Dynamic damage assessment of resistance spot welding for dissimilar plates by using model updating approach / Nazrotul Afina Nazri

By: Material type: TextTextPublisher: Kuantan, Pahang : UMP, 2019Copyright date: © 2019Description: xiv, 116 pages : illustrations ; 30 cm. + 1 CD-ROMContent type:
  • text
  • text
Media type:
  • unmediated
  • computer
Carrier type:
  • volume
  • computer disc
ISBN:
  • THE0008458(Local)
Subject(s): Dissertation note: Thesis (Master of science) -- Universiti Malaysia Pahang – 2019 Abstract: Top hat plate structure was fabricated in this study to represent floor pan compartment of body in white (BIW) structure, by using two dissimilar materials which are mild steel and stainless steel that were joined together through resistance spot weld (RSW) process. Objectives of this study were to determine and compare modal properties of RSW between dissimilar materials using FEA and EMA approaches, to minimize the discrepancies between FEA and EMA using sensitivity analysis, model updating procedure and lastly, to evaluate the damage assessment of RSW through experiment and simulation study. The tested structure was designed in CAD software, and normal mode analysis of FEA using MSC Nastran Patran was performed to find modal parameter along with modal testing using impact hammer with roving accelerometer method which was carried on to the specimen by having 50 measurement points. This study was continued with joining strategy analysis by applying Rigid Body Element (RBE), Bar Element (CBAR), Weld Element (CWELD) and Beam Element (CBEAM) at the real spot weld connection and their results were compared with EMA. After finding the most reliable joining strategy, model updating was conducted to reduce discrepancies between FEA joining and EMA. At the end, damage was introduced on both intact FEA and EMA structure and any changes in modal parameters were observed by removing four spot welds at the edge of tested structure. From the analysis, CWELD has been found as the most reliable joining to represent RSW connection and for sensitivity analysis, Young’s Modulus and density for both mild steel and stainless steel were selected for model updating, which was successfully performed on this joining. For damages study, it was observed that the value of natural frequencies has significant decrement after the damage was rendered in both FEA and EMA studies, which also resulted in a shift of frequency to a lower value in FRF graph. As the conclusion, CWELD was the most suitable joining to represent RSW and the presence of damage reduced natural frequency values which affected the modal properties of a structure.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Copy number Status Date due Barcode
Thesis Thesis UMPLIB PEKAN Reference Reference FKM .N39 2019 r Thesis (Browse shelf(Opens below)) 1 Not for loan T000000159
Thesis Thesis UMPLIB PEKAN CD12245 (Browse shelf(Opens below)) 1 Not for loan T000000160

Faculty of Mechanical Engineering

Thesis (Master of science) -- Universiti Malaysia Pahang – 2019

Includes bibliographical references

Top hat plate structure was fabricated in this study to represent floor pan compartment of body in white (BIW) structure, by using two dissimilar materials which are mild steel and stainless steel that were joined together through resistance spot weld (RSW) process. Objectives of this study were to determine and compare modal properties of RSW between dissimilar materials using FEA and EMA approaches, to minimize the discrepancies between FEA and EMA using sensitivity analysis, model updating procedure and lastly, to evaluate the damage assessment of RSW through experiment and simulation study. The tested structure was designed in CAD software, and normal mode analysis of FEA using MSC Nastran Patran was performed to find modal parameter along with modal testing using impact hammer with roving accelerometer method which was carried on to the specimen by having 50 measurement points. This study was continued with joining strategy analysis by applying Rigid Body Element (RBE), Bar Element (CBAR), Weld Element (CWELD) and Beam Element (CBEAM) at the real spot weld connection and their results were compared with EMA. After finding the most reliable joining strategy, model updating was conducted to reduce discrepancies between FEA joining and EMA. At the end, damage was introduced on both intact FEA and EMA structure and any changes in modal parameters were observed by removing four spot welds at the edge of tested structure. From the analysis, CWELD has been found as the most reliable joining to represent RSW connection and for sensitivity analysis, Young’s Modulus and density for both mild steel and stainless steel were selected for model updating, which was successfully performed on this joining. For damages study, it was observed that the value of natural frequencies has significant decrement after the damage was rendered in both FEA and EMA studies, which also resulted in a shift of frequency to a lower value in FRF graph. As the conclusion, CWELD was the most suitable joining to represent RSW and the presence of damage reduced natural frequency values which affected the modal properties of a structure.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us