<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02933ntm a2200349 i 4500</leader>
  <controlfield tag="003">MY-KuUP</controlfield>
  <controlfield tag="005">20260611173911.0</controlfield>
  <controlfield tag="006">t||||fr|||| 000 0 </controlfield>
  <controlfield tag="007">ta</controlfield>
  <controlfield tag="008">260611s20242024my a|||fr|||| 000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0010596 (Local)</subfield>
    <subfield code="q">Hardback</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMPSA</subfield>
    <subfield code="b">eng</subfield>
    <subfield code="c">UMPSA</subfield>
    <subfield code="e">rda</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">FTKKP .E86 2024 r Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Esmond, Chewzhi Yu,</subfield>
    <subfield code="e">author.</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Cfd simulation study on the flame propagation mechanism by combining the reversal flowand re-ignition effect in vented dust explosion /</subfield>
    <subfield code="c">Esmond Chewzhi Yu</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="1">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMPSA,</subfield>
    <subfield code="c">2024</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="4">
    <subfield code="c">&#xA9; 2024</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">x, 32 pages :</subfield>
    <subfield code="b">illustrations ;</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="2">rdacontent</subfield>
    <subfield code="a">text</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="2">rdamedia</subfield>
    <subfield code="a">unmediated</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="2">rdacarrier</subfield>
    <subfield code="a">volume</subfield>
  </datafield>
  <datafield tag="347" ind1=" " ind2=" ">
    <subfield code="2">rda</subfield>
    <subfield code="a">text file</subfield>
    <subfield code="b">PDF</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Faculty of Chemical and Process Engineering Technology</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Final Year Report (Bachelor of Chemical Engineering Technology) -- Universiti Malaysia Pahang Al-Sultan Abdullah - 2024</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Include bibliographical reference</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">The study presented in this paper focuses on using computational fluid dynamics (CFD) simulations to investigate the flame propagation mechanism in vented dust explosions. CFD simulations have become a popular tool for studying various aspects of vented dust explosions, including flame propagation. The combined effects of reversal flow and re-ignition, which are significant factors in the severity of these explosions, are examined. Reversal flow occurs when the hot gases from an initial explosion expand and then contract, creating a low- pressure region behind the explosion front. This reversal in flow direction can pull unburned dust and air back into the flame front, leading to a more intense and prolonged explosion. The reignition effect refers to the ignition of unburned fuel particles by hot gases from the initial explosion, resulting in a second, more powerful explosion. These effects are particularly pronounced when there is a high concentration of combustible dust. The CFD simulations carried out in this study involve modeling the geometry, defining physical and chemical characteristics, discretizing the system using a numerical grid, solving the governing equations, and analyzing the results. The simulation was used by a pressure-based solver. This study concludes that the effect of reversal flow and reignition was said to be interrelated. By gaining insights into the behavior of flame propagation in vented dust explosions, this research contributes to a better understanding of the process, enabling improved safety measures and more efficient system designs.</subfield>
  </datafield>
  <datafield tag="610" ind1="2" ind2="0">
    <subfield code="a">Faculty of Chemical and Process Engineering Technology</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2=" ">
    <subfield code="a">Universities and colleges</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2=" ">
    <subfield code="a">Theses</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="u">https://umpir.ump.edu.my/id/eprint/46949</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">lcc</subfield>
    <subfield code="c">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2026-06-11</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">FTKKP .E86 2024 r Bc.</subfield>
    <subfield code="p">T000004135</subfield>
    <subfield code="r">2026-06-11 17:39:21</subfield>
    <subfield code="w">2026-06-11</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">104985</subfield>
    <subfield code="d">104991</subfield>
  </datafield>
</record>
