<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02980ntm a2200349 i 4500</leader>
  <controlfield tag="003">MY-KuUP</controlfield>
  <controlfield tag="005">20260812174650.0</controlfield>
  <controlfield tag="006">t|||||r|||| 000 0</controlfield>
  <controlfield tag="007">ta</controlfield>
  <controlfield tag="008">260812t20252025my a|||fr|||| 000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0010969 (Local)</subfield>
    <subfield code="q">Hardback</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMPSA</subfield>
    <subfield code="b">eng</subfield>
    <subfield code="c">UMPSA</subfield>
    <subfield code="e">rda</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">FSTI .A36 2025 r Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Wan Akmal Bin Wan Anuar,		 						 	,	,</subfield>
    <subfield code="e">author.</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Evaluation of heat stress index associated with heat strain among workers in palm oil plantations /</subfield>
    <subfield code="b"></subfield>
    <subfield code="c">Wan Akmal Bin Wan Anuar</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="1">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMPSA,</subfield>
    <subfield code="c">2025</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="4">
    <subfield code="c">&#xA9; 2025</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xiii, 67 pages :</subfield>
    <subfield code="b">illustrations ;</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="2">rdacontent</subfield>
    <subfield code="a">text</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="2">rdamedia</subfield>
    <subfield code="a">unmediated</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="2">rdacarrier</subfield>
    <subfield code="a">volume</subfield>
  </datafield>
  <datafield tag="347" ind1=" " ind2=" ">
    <subfield code="2">rda</subfield>
    <subfield code="a">text file</subfield>
    <subfield code="b">PDF</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Faculty of Industrial Sciences and Technology</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Final Year Report (Bachelor Degree Of Occupational Safety And Health) -- Universiti Malaysia Pahang Al-Sultan Abdullah - 2025</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Include bibliographical reference</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Heat Stress is one of the critical components that can affect human health particularly among workers due to exposure from hot environment. This study aims to evaluate the heat stress associated with heat strain level among palm oil plantation workers by assessing environmental heat stress, measuring workers&#x2019; heat strain level and determining the relationship between these variables. Using the combination measurements and questionnaires, environmental heat stress was identified by Wet Bulb Glob Temperature (WBGT) through parameters including ambient temperature, relative humidity and radiant heat. Workers&#x2019; heat strain level was assessed through a set of questionnaires that included worker characteristics, physical activity and perceived symptoms, perception of workplace ambient, working attire and personal protective equipment and workplace setting. The outcomes gained show that environmental heat stress in palm oil plantation sectors is high risk particularly during peak working hours which exceed the threshold limit value (TLV) recommended by American Conference of Governmental Industrial Hygienists (ACGIH). However, workers who experience heat stress are not impactful towards their heat strain level since the heat strain score index shows green zone (&#x2264; 13.5) area which is considered safe. Therefore, the result obtained from this study is that there is no relationship between environmental heat stress and heat strain level among palm oil plantation workers. From the findings, the level of exposure heat exposure can be determined as high risk but not affect the workers heat strain. Thus, safe work practices can be maintained.</subfield>
  </datafield>
  <datafield tag="610" ind1="2" ind2="0">
    <subfield code="a">Faculty of Industrial Sciences and Technology</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Universities and colleges</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Theses</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="u">https://umpir.ump.edu.my/id/eprint/46288</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">lcc</subfield>
    <subfield code="c">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2026-08-12</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">FSTI .A36 2025 r Bc.</subfield>
    <subfield code="p">T000003804</subfield>
    <subfield code="r">2026-08-12 17:48:43</subfield>
    <subfield code="w">2026-08-12</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">105475</subfield>
    <subfield code="d">105481</subfield>
  </datafield>
</record>
