<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>03013nam a2200241 a 4500</leader>
  <controlfield tag="001">vtls000041220</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204414.0</controlfield>
  <controlfield tag="008">090811t2008    my a   f m    000 0 eng|d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0007326(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905141457</subfield>
    <subfield code="b">fawwaz</subfield>
    <subfield code="c">201107132231</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141654</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141638</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="y">200908110827</subfield>
    <subfield code="z">ida84</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TL271.5 .A43 2008 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Alauddin Hafiz Yusof</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Air conditioning study for automotive application /</subfield>
    <subfield code="c">Alauddin Hafiz Yusof</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">Air conditioning study for automotive application</subfield>
    <subfield code="h">[electronic resource]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2008</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">63 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2008</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Air  conditioning  is  a process by which  air  is  cooled or heated,  cleaned  or  filtered,   and  circulated  or  recirculated.  Air  conditioning  had  become  a  standard  option  on   most vehicle for enhancing comfort and safety. Most of automotives air conditioning   system, the compressor is a belt-driven coupled to the engine. This means the cycling   rate  is  directly  related  to  the  engine  speed.  Based  on  the  situation,  the  air   conditioning test rig was built to understand clearly about the air conditioning system   including the vapor compression refrigeration cycle in the system and the function of   each component in the system. There are four locations of temperature measurement   were  selected  in  order  to  develop  the  test  rig. These  locations  are  at  the  inlet  and   outlet of the compressor, the outlet of the condenser, and the inlet of the evaporator,   respectively. The pressure was measured at  the  low pressure side and high pressure   side which are at the outlet of the evaporator and inlet of the condenser, respectively.   All of the parameters are measured during the cycle and were analyzed by using the   properties table for refrigerant-134a and the p-h diagram for refrigerant-134a in order   to  determine  the  heat  rejection,  cooling  effect,  work  of  compressor  and  the   coefficient  of  performance  (COP)  of  the  air  conditioning  system.  The  refrigerant   mass  flow  rate was  calculated  based  on  the  theory  calculation. The  heat  rejection,   cooling effect, work of compressor,  refrigerant mass  flow  rate, and  the COP of  the   air conditioning system were investigated at variable speed of compressor. The COP   of the system was decreasing as the increasing of the compressor speed. The COP of   the system at  the compressor speed of 1500 rpm  is 13.48 and was decreasing  to  the   value of 10.33, 7.82,  and 6.53 when  the  compressor  speed was  increasing  to 2000   rpm, 2500 rpm, and 3000 rpm, respectively.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Automobiles</subfield>
    <subfield code="x">Air conditioning</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TL271.5 .A43 2008 rs Bc.</subfield>
    <subfield code="p">0000038678</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 3537 | TL271.5 .A43 2008 rs Bc.</subfield>
    <subfield code="p">0000038679</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">1484</subfield>
    <subfield code="d">1490</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5200*6500*9992</subfield>
  </datafield>
</record>
