<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02563nam a2200253 a 4500</leader>
  <controlfield tag="001">vtls000038420</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204417.0</controlfield>
  <controlfield tag="008">090622t2008    my a   f m    000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0006816(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905291238</subfield>
    <subfield code="b">amirul</subfield>
    <subfield code="c">201107132244</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141635</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141609</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="y">200906221245</subfield>
    <subfield code="z">kam</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TK3226 .A35 2008 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Wan Mohd Afiq Nazman Wan Anuar</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Study of voltage sag in power system with six-phase transmission line /</subfield>
    <subfield code="c">Wan Mohd Afiq Nazman Bin Wan Anuar</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">Study of voltage sag in power system with six-phase transmission line</subfield>
    <subfield code="h">[electronic resource]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2008</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">58 p. :</subfield>
    <subfield code="b">ill. ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Electrical Engineering (Power system)) -- Universiti Malaysia Pahang - 2008</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Voltage sags are the short durations in root-mean-square (RMS) rated AC voltage occur during faults may cause miss-operations to the customer&#x2019;s equipment and loads of power system and recognized as the most important power quality problem. However, this thesis investigate the sag event which is caused by short circuit (three-phase-to-ground fault and six-phase-to-ground fault) on the double three phase transmission line and conversion of phase double circuit to the six phase single circuit transmission line. Six phase were chosen for this project because six phase enhance power transfer capability and becoming the area of growing interest in the power system industry. This thesis also presents the comparisons between voltage reductions at the terminal bus for both three and six phase cases. Simulation at steady state and transient state of the system proposed is simulated using PSCAD/EMTDC.  The system that used in this thesis was four buses transmission line. The simulation result shows that converted double three phase to six phase transmission experienced lower voltage sags level at other bus terminal than double three phase system due to three-phase-to-ground fault and six phase-to-ground fault if the fault happen at bus three, but for faulted bus, the it&#x2019;s experienced the same percentage voltage sag. For fault happen between transformers in six phase operation, 20% to 45% of the voltage was improve at the faulted bus compare to three phase system.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Short circuits</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Electric circuits</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TK3226 .A35 2008 rs Bc.</subfield>
    <subfield code="p">0000037336</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 3232 | TK3226 .A35 2008 rs Bc.</subfield>
    <subfield code="p">0000037337</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">1576</subfield>
    <subfield code="d">1582</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5200*6500*6501*9992</subfield>
  </datafield>
</record>