<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02885nam a2200229 a 4500</leader>
  <controlfield tag="001">vtls000040209</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204419.0</controlfield>
  <controlfield tag="008">090714t2009    my a   f m    000 0 eng|d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0006192(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905151720</subfield>
    <subfield code="b">aida</subfield>
    <subfield code="c">201111250812</subfield>
    <subfield code="d">Fida</subfield>
    <subfield code="c">201107132244</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200911091651</subfield>
    <subfield code="d">kam</subfield>
    <subfield code="y">200907140951</subfield>
    <subfield code="z">ida84</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TJ223.T4 N67 2009 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Nor Mazlee Norazmi</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Temperature-control system/</subfield>
    <subfield code="c">Nor Mazlee Bin Norazmi</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2009</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">43 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Electrical Engineering (Control and Instrumentation)) -- Universiti Malaysia Pahang - 2009</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">This project title is  &#x2018;Temperature-Control System&#x2019; which is a particular  system for server room. For the circuit, it consists of temperature sensor,PIC,LCD,driver circuits, AC air heater and AC motor. Three drivers are used for  triggering process  to switch on the AC heater and another two are for triggering levels of the motor.This motor will operate based on two  temperature ranges and that means, it has two levels of speed.The function of this system is for controlling the temperature value inside of a regular room automatically. It will operate based on the values or ranges of  temperature in the room which is detected by the temperature sensor.If the temperature in the first range (0&#xBA;C to 15&#xBA;C ),the air heater  will be operated to heat the server room which in very cold temperature.If it is in the second range(16&#xBA;C to 25&#xBA;C) this system will not be enabled because it&#x2019;s achieving normal temperature range.If temperature in range 26&#xBA;C to 40&#xBA;C,motor will be triggered for level 1 to decrease the temperature value. If it is more than 40&#xBA;C, the motor will be triggered for level 2 and its speed becomes faster at this level. The both output devices are important  to maintain the temperature value in the room .This system can be categorized in automatic system class and solve users&#x2019; problem.The problem always happen if air-conditioner  broke down and definitely, the room becomes hotter or temperature increases. Besides that, temperature becomes too cold and influenced by weather from outside of the sever room. With that, the motor and air heater are important to keep maintaining the sever room in suitable temperature range. This system has temperature sensor which may detect the surrounding temperature and the outputs are operated based on the temperature ranges.Programming of the PIC is a important basic to read  data or accept signal from the sensor .In the same time,it maintains the temperature inside of the room  and make it suitable for user.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Temperature control</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TJ223.T4 N67 2009 rs Bc.</subfield>
    <subfield code="p">0000037899</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 3324 | TJ223.T4 N67 2009 rs Bc.</subfield>
    <subfield code="p">0000037900</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">1635</subfield>
    <subfield code="d">1641</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5020*5200*6500*9992</subfield>
  </datafield>
</record>
