<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Power quality analysis based on harmonic distortion level in FKEE lab, UMP</title>
  </titleInfo>
  <titleInfo type="alternative">
    <title>Power quality analysis based on harmonic distortion level in FKEE lab, UMP</title>
  </titleInfo>
  <name type="personal">
    <namePart>Ahmad Kamil Fadir</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">theses</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Kuantan, Pahang</placeTerm>
    </place>
    <publisher>UMP</publisher>
    <dateIssued>2009</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <form authority="gmd">electronic resource</form>
    <extent>65 p. : ill. (some col.) ; 30 cm. + 1 computer disc</extent>
  </physicalDescription>
  <abstract>Power quality  is defined as any power problem manifested  in voltage, current or   frequency  deviation  that  results  in  failure  or  misoperation  of  customer  equipment.    Harmonic  is  sinusoidal  voltage  or  currents  which  has  frequencies  that  are  integer   multiples  of  the  fundamental  frequency  (frequency  at  which  the  supply  system  is   designed to operate, normally 50 or 60 Hz).Firstly the harmonic current and voltage were    get at substation board  in FKEE  lab by using power quality  analyzer. After a week,  the   data  transferred  to  the  computer by  using FLUKEVIEW  software. Then,  the data  were   compared to International Standard which is AS61000.3.6 and IEEE 519 by using Visual   Basic (Microsoft Web Developer) to display it.  The results show us that all the data were   satisfy with the standards. During the study period (between 12 pm until 6 pm) at the lab,    there were the peak period of harmonic but from 7 pm to 7 am, the harmonics were lower   than  before.  Its  shows  us  that  the  usage of  the  electrical  equipment  such  as  computers,    lighting, motors were higher during our  lab period. So,  from  the analysis we know when   is the peak time of harmonic will occur and the sources of the harmonic. Besides that,  we   also know about the effect of the harmonic distortion on electrical equipment.</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Ahmad Kamil Bin Fadir</note>
  <note>Project paper (Bachelor of Electrical Engineering (Power Systems)) -- Universiti Malaysia Pahang - 2009</note>
  <subject authority="lcsh">
    <topic>Electric power systems</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Power transmission</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Harmonic analyzers</topic>
  </subject>
  <identifier type="isbn">THE0006464(Local)</identifier>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">090714</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251114204419.0</recordChangeDate>
    <recordIdentifier source="KUKTEM">vtls000040213</recordIdentifier>
  </recordInfo>
</mods>