<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02408nam a2200265 a 4500</leader>
  <controlfield tag="001">vtls000045890</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204420.0</controlfield>
  <controlfield tag="008">100524t2009    my dao f m    000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0005672(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905211103</subfield>
    <subfield code="b">hanafiah</subfield>
    <subfield code="c">201107132244</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">201103301003</subfield>
    <subfield code="d">ida</subfield>
    <subfield code="c">201005311559</subfield>
    <subfield code="d">ida</subfield>
    <subfield code="y">201005241415</subfield>
    <subfield code="z">ida</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TA357 .S87 2009 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Suriani Abd Rahman</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="4">
    <subfield code="a">The effect of stent void area on hemodynamics in cerebral aneurysm /</subfield>
    <subfield code="c">Suriani Binti Abd Rahman</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">The effect of stent void area on hemodynamics in cerebral aneurysm</subfield>
    <subfield code="h">[electronic resource]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2009</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xiii, 67 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Bibliography : p. 58-59</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">The purpose of this study is to develop modeling methodologies to understand how different stent void area alter the aneurysmal flow. Four difference stents design with difference void area were created with suitable geometry for Computational Fluid Dynamics (CFD) analysis. The velocity profile and pressure distribution after installing the device had been identified from the selected stent. These four types of design will be referred as stent type I, II, III, and IV and these stent was tested in an aneurysm model. The simulation of the model was studied under incompressible, Newtonian, viscous, non-pulsatile condition. In this study, we need to determine the correlation between stent porous area and blood flow and to determine the flow behavior in stented aneurysm. We found the stent design affected a cerebral aneurysm hemodynamic. The different of stent structural pattern produces the different results of flow field around the stented aneurysm. The minimum velocity had improved after stents insertion and the type IV with less void area results most optimized. Other than that, the peak pressure will also decrease after the stent implantation. As expected, the lowest peak pressure results from stent type IV. The result shows that the stent with the lowest void area gives the best performance.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Fluid dynamics</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Hemodynamics</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TA357 .S87 2009 rs Bc.</subfield>
    <subfield code="p">0000044307</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 4177 | TA357 .S87 2009 rs Bc.</subfield>
    <subfield code="p">0000044308</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">1648</subfield>
    <subfield code="d">1654</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5040*5200*6500*6501*9992</subfield>
  </datafield>
</record>