<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <nonSort>A </nonSort>
    <title>study of pipe leak source location using single channel acoustic emissions (AE) technique</title>
  </titleInfo>
  <name type="personal">
    <namePart>Mohd Firzikri Abd Sata</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">theses</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Kuantan, Pahang</placeTerm>
    </place>
    <publisher>UMP</publisher>
    <dateIssued>2009</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>xv, 67 p. : ill. (some col.) ; 30 cm. + 1 CD-ROM</extent>
  </physicalDescription>
  <abstract>This project was  carried out  as  a  study of pipe  leak  source  location using  single channel acoustic emissions (AE) technique. The objectives of this project are to study a reliable and affordable system capable of monitoring pipe leak and also to locate the source of the pipe leak using AE technique. A test rig consists of the pipe without leak and the pipe with leak was developed using circumferential of a galvanized steel pipe to run the experiments. The fluid used was water throughout the experiments. The flow of the water was controlled by a ball valve. The source of  the AE signals was  from  the  leak and  it was captured using AE sensor with the help of Acoustic Emission Detector 2.1.3 software. For all pipe conditions, the values of hits, counts and RMS (average, maximum and minimum) were recorded and analyzed. All  the  values  recorded were  compared  between  the  pipe without  leak  and  the pipe with leak (full open valve and full close valve). The results were gained from 8 marked points each  for all pipe conditions. The  results showed  that  there was no AE activities on the pipe without leak while for the pipe with leak, the AE activities are greater for full close valve  than  full open valve.  In  addition,  two  equations  for  locating  the  source of  the pipe leak were  introduced from  the RMS against distance graft. For  the pipe with  leak and full open valve, the equation is y = 0.011 x + 0.249. For the pipe with leak and full close valve,   the equation is y = 0.017 x + 0.199.</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Mohd Firzikri Bin Abd Sata</note>
  <note>Project paper (Bachelor of  Mechanical Engineering) -- Universiti Malaysia Pahang - 2009</note>
  <note>Bibliography : p. 55-57</note>
  <subject authority="lcsh">
    <topic>Pipelines</topic>
    <topic>Safety and measures</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Leak detectors</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Acoustic emission</topic>
  </subject>
  <identifier type="isbn">THE0006449(Local)</identifier>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">100504</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251114204425.0</recordChangeDate>
    <recordIdentifier source="KUKTEM">vtls000045509</recordIdentifier>
  </recordInfo>
</mods>