<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02612nam a2200265 a 4500</leader>
  <controlfield tag="001">vtls000045568</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204426.0</controlfield>
  <controlfield tag="008">100505t2009    my ao  f m    000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0006238(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905161213</subfield>
    <subfield code="b">aida</subfield>
    <subfield code="c">201107132317</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="y">201005051351</subfield>
    <subfield code="z">ida</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TJ260 .K43 2009 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Khaider Abu Bakar</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Effect of nozzle angle on jet impingement cooling system /</subfield>
    <subfield code="c">Khaider Bin Abu Bakar</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">Effect of nozzle angle on jet impingement cooling system</subfield>
    <subfield code="h">[electronic resource]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2009</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xvi, 74 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2009</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Bibliography : p. 48</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Cooling system using jet impingement is already widely used in industries nowadays. There were various approaches that have been investigated in order to produce more efficient jet impingement cooling system. This thesis is study about the effect of the nozzle angle on jet impingement in order to identify the relationship in heat transfer. Besides, investigation on spacing distance between nozzle&#x2019;s edge to the impingement surface and Reynolds number at certain angle also identified in this study. Those studies are needed parallel to the current researchers endeavor for future development of cooling system in global industries. The experiment were perform by vary 3 major parameters such as angle of the nozzle (30&#x2070;, 45&#x2070;, 60&#x2070;, and 90&#x2070;), distance between nozzle&#x2019;s edge to the impinge surface (H/d= 2, 4, 6, and 8) and also Reynolds number (Re= 2300, 1960,930 and 500).The heat source are heated at 100 &#x2070;C and cooled down by the flow of air from the nozzle. The heat source temperature after cooling are measured and collected. The result discovers about the relationship nozzle angle for jet impingement cooling system which is heat transfer are more efficient when the angle of nozzle approaching to the normal line as the Nusselt Number are more higher at 90&#x2070; in range 31.5 w/m2K of heat transfer coefficient compare to the lower angles of the nozzle. Furthermore, higher Reynolds number and close range of distance between nozzle&#x2019;s edges to impingement surface will also gives high Nusselt number which means both also effective cooling effects for the systems.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Heat</subfield>
    <subfield code="x">Transmission</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Nozzles</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TJ260 .K43 2009 rs Bc.</subfield>
    <subfield code="p">0000044435</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 4241 | TJ260 .K43 2009 rs Bc.</subfield>
    <subfield code="p">0000044436</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">1814</subfield>
    <subfield code="d">1820</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5040*5200*6500*6501*9992</subfield>
  </datafield>
</record>
