02725nam a2200313 a 4500001001400000003000700014005001700021008004200038020002200080039008300102040000800185090003000193100002000223245011000243246010800353260003400461300006300495502012000558504002800678520124900706650002301955650003101978650001102009650001102020952012402031952013402155999002502289999009702314vtls000051871KUKTEM20251114204441.01103111t2010 my a f m 000 0 eng d aTHE0005829(Local) 9a201905131538baidac201110041225dFidac201107140037dVLOADy201103111659zida aUMP aTA418.84 .M89 2010 rs Bc.0 aMuzakkir Shukri10aAnalysis the effect of different type valve use at different pressure in piping system /cMuzakkir Shukri3 aAnalysis the effect of different type valve use at different pressure in piping systemh[computer file] aKuantan, Pahang :bUMP,c2010 axv, 70 p. :bill. (some col.) ;c30 cm. +e1 computer disc aProject paper (Bachelor of Mechanical Engineering with Automotive Engineering) -- Universiti Malaysia Pahang - 2010 aBibliography : p. 60-613 aThis project was carried out as a study of flow rate using a single channel acoustic emission (AE) technique. The objective of this project is to study the effect of ball valve, brass gate valve and brass stop cock valve to flow rate using AE technique. A test rig consists of the circumferential galvanized steel pipe, ball valve, gate valve and stop cock valve to run the experiments. The fluid used was water throughout the experiments. The pressure of water was controlled by a valve. The source of AE signal was from the valve and it was captured using AE sensor with the help of Acoustic Emission Detector 2.1.3 software. For all valve conditions, the value of hits, count and RMS (average, maximum and minimum) were recorded and analyzed. All the value recorded were compared among the ball valve, gate valve and stop cock valve. The results were gained from 10 marked points each for all type of valve. The result showed that there was no AE activity on the pipe without valve, the AE activities are greater for high pressure or full close valve. In addition from the RMS against distance graft, RMS value increased when pressure is increased. From the flow rate against RMS graf show that flow rate will decrease when RMS is increased. 0aAccoustic emission 0aAccoustic emission testing 0aValves 0aPiping 00104076a20000b20000d2019-09-04l0oTA418.84 .M89 2010 rs Bc.p0000054195r2019-09-04 00:00:00t1w2019-09-04yPSM 00104071a20000b20000d2019-09-04l0oCD 5113 | TA418.84 .M89 2010 rs Bc.p0000054196r2019-09-04 00:00:00t1w2019-09-04yPSM aVIRTUA40c2259d2265 aVTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5040*5200*6500*6501*6502*6503*9992