<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02606nam a2200265 a 4500</leader>
  <controlfield tag="001">vtls000052189</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204445.0</controlfield>
  <controlfield tag="008">110322t2010    my da  f m    000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0003258(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905161109</subfield>
    <subfield code="b">irma</subfield>
    <subfield code="c">201112301301</subfield>
    <subfield code="d">ida</subfield>
    <subfield code="c">201110041239</subfield>
    <subfield code="d">Fida</subfield>
    <subfield code="c">201107140040</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="y">201103221558</subfield>
    <subfield code="z">Fida</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TD756.5 .I58 2010 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Intan Safinaz Ismail</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="2">
    <subfield code="a">A comparative study on anaerobic treatment between ponding system and digester tank system for palm oil mill effluent (POME) treatment /</subfield>
    <subfield code="c">Intan Safinaz Ismail</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2010</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xiv, 73 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Civil Engineering &amp; Earth Resources) -- Universiti Malaysia Pahang - 2010</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Bibliography : p. 64-65</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Palm oil is one of the important industrial sectors in Malaysia. Every year, the production of palm oil increased rapidly. As the production of palm oil increased, more palm oil mill effluent (POME) is generated annually. The total annual quantity of wastewater generated is estimated to be 1.8&#xD7;106m3. This situation contributed to more study on the technology of treatment of the POME. Raw POME comprises of water-soluble components of the palm fruits as well as some suspended materials like palm fibre and oil and it cannot be discharged into the watercourse directly. The effluent must be treated to acceptable quality before it can be discharged. Comparison on conventional system and alternative system for anaerobic treatment between ponding system and digestion tank treatment system was used for treatment POME. The resources of this data are taken from the selected Palm oil Mill Plantations. The main parameters for POME are BOD, COD, Suspended Solid, and Oil &amp; Grease. The reduction of main parameters for Ponding System and Digester Tank System was determine which is BOD, 96.88% and 98.06%, COD, 90.60% and 92.70%, SS, 94.03% and 96.83% and O&amp;G, 97.21% and 81.33%. Meanwhile, the quality, effectiveness and the advantages and disadvantages for both systems also were determined. The findings show that alternative treatment system which is Digester Tank System having efficiency, effective and ability to treat POME better than conventional treatment system.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Constructed wetlands</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Land treatment of wastewater</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Water</subfield>
    <subfield code="x">Biological treatment</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TD756.5 .I58 2010 rs Bc.</subfield>
    <subfield code="p">0000054645</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 5148 | TD756.5 .I58 2010 rs Bc.</subfield>
    <subfield code="p">0000054646</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">2351</subfield>
    <subfield code="d">2357</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5020*5040*5200*6500*6501*6502*9992</subfield>
  </datafield>
</record>
