<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02193nam a2200265 a 4500</leader>
  <controlfield tag="001">vtls000052287</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204445.0</controlfield>
  <controlfield tag="008">110325t2010    my da  f m    000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0006427(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905131519</subfield>
    <subfield code="b">amirul</subfield>
    <subfield code="c">201211011408</subfield>
    <subfield code="d">Fida</subfield>
    <subfield code="c">201107140041</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">201103250947</subfield>
    <subfield code="d">ida</subfield>
    <subfield code="y">201103250945</subfield>
    <subfield code="z">ida</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TJ853 .B57 2010 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Muhammad Bisharul Hafi Ab Jalil</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Determination of heat transfer coefficient using experimental values of pressure drop of a single phase fluid /</subfield>
    <subfield code="c">Muhammad Bisharul Hafi Ab Jalil</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2010</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xv, 71 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 CD-ROM</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang - 2010</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Bibliography: p. 50-53</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Analogical procedure to obtain the heat transfer coefficient for fluid flowing inside tube in turbulent range with carbon nanotubes is carried out. A regression equation valid for both water and nanofluid is developed by making use of Colburn analogy to estimate the Nusselt number. Heat transfer coefficient and pressure drop with carbon nanotubes has been analogically determined with different Prandtl number and volume concentration. Based on the analysis, the regression equation showed considerable deviation with the Gnielinski correlation and considered reliable in turbulent flow for single-phase fluid. The results also showed that convective heat transfer flow in plain tube is enhanced significantly by the existence of carbon nanotubes when compared with water using the regression equation developed. It is also observed that heat transfer coefficient for carbon nanotubes having volume concentration of 0.1% is 48.16% higher compared with water at 20,000 Reynolds number. Heat transfer coefficient is also enhanced with the increase of Prandtl number and volume concentration with maximum value of 0.5%.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Nanofluids</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Fluidic devices</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Heat</subfield>
    <subfield code="x">Transmission</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TJ853 .B57 2010 rs Bc.</subfield>
    <subfield code="p">0000053873</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 4952 | TJ853 .B57 2010 rs Bc.</subfield>
    <subfield code="p">0000053874</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">2377</subfield>
    <subfield code="d">2383</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5020*5040*5200*6500*6501*6502*9992</subfield>
  </datafield>
</record>
