<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02810nam a2200277 a 4500</leader>
  <controlfield tag="001">vtls000045079</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204455.0</controlfield>
  <controlfield tag="008">100204t2009    my a   f m    000 0 eng|d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0003257(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905161108</subfield>
    <subfield code="b">irma</subfield>
    <subfield code="c">201108030938</subfield>
    <subfield code="d">Fida</subfield>
    <subfield code="c">201107132306</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">201002090933</subfield>
    <subfield code="d">ida</subfield>
    <subfield code="y">201002041107</subfield>
    <subfield code="z">ida</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TD756.5 .H36 2009 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Muhammad Hanafi Ahmad</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Municipal wastewater treatment using constructed wetland :</subfield>
    <subfield code="b">removal of chemical oxygen demand (COD) and total suspended solid (TSS) /</subfield>
    <subfield code="c">Muhammad Hanafi Ahmad</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">Municipal wastewater treatment using constructed wetland :</subfield>
    <subfield code="b">removal of chemical oxygen demand (COD) and total suspended solid (TSS)</subfield>
    <subfield code="h">[computer file]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2009</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">42 p. :</subfield>
    <subfield code="b">ill. ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Chemical Engineering (Biotechnology)) -- Universiti Malaysia Pahang - 2009</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Bibliography : p. 34-36</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">The  lab-scale of surface  flow constructed wetland  (SF) was applied  to  treat municipal wastewater  for  removal of Chemical Oxygen Demand  (COD) and Total Suspended  Solid  (TSS).  The aim  of  this  study  was  to  determine  the  percentage removal of Chemical Oxygen Demand (COD) and Total Suspended Solid (TSS) at different concentration of wastewater and at different number of treatment cycle by using  constructed  wetland  treatment  system.  Two  different  concentration  of  wastewater were used which  is diluted wastewater and non diluted wastewater and the treatment system was run for 10 days of treatment. The sample also treated with one  treatment  cycle  and  two  treatment  cycles.  For  the  purpose  of  this  study,  the treatment  system consists of 4  stages of  treatment and  it  took 10 days  to complete one cycle  treatment, while  for  two cycle  treatment  it  took 20 days. The 1st and 3rd stage is treated by gravel, while 2nd and 4th stage is treated by Pistia stratioes. From result  obtained,  it  shows  that  treatment  system  with  diluted  wastewater  by  two treatment cycle was more efficient and gave the highest percentage removal of COD  (92.5%) and TSS (91.4%), while DO level increased by 120%. Hence, the removal of COD and TSS complied with  the  requirement of  the  sewage effluents  standard. Results  from  this  study indicate  that  the  Surface  Flow  Constructed  Wetland  is suitable and can be develops as one of the technology treatment system in the future.-Author-</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Sewage</subfield>
    <subfield code="x">Purification</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Constructed wetlands</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Water</subfield>
    <subfield code="x">Biological treatment</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TD756.5 .H36 2009 rs Bc.</subfield>
    <subfield code="p">0000043017</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 4040 | TD756.5 .H36 2009 rs Bc.</subfield>
    <subfield code="p">0000043018</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">2653</subfield>
    <subfield code="d">2659</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5040*5200*6500*6501*6502*9992</subfield>
  </datafield>
</record>
