<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02602nam a2200241 a 4500</leader>
  <controlfield tag="001">vtls000040407</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204456.0</controlfield>
  <controlfield tag="008">090715t2009    my ao  f m    000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0006802(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905291142</subfield>
    <subfield code="b">amirul</subfield>
    <subfield code="c">201107132243</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141648</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141628</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="y">200907151731</subfield>
    <subfield code="z">kam</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TK3091 .I89 2009 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Muhamad Iszuan Hamdan</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Impact of rotating machines on harmonic distortion in power distribution systems /</subfield>
    <subfield code="c">Muhamad Iszuan Bin Hamdan</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">Impact of rotating machines on harmonic distortion in power distribution systems</subfield>
    <subfield code="h">[electronic resource]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2009</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">65 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Electrical Engineering (Power Systems)) -- Universiti Malaysia Pahang - 2009</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Harmonic cause of distortion of the voltages and current waveforms, which have adverse effects on electrical equipment. Harmonics are one of the major power quality concerns. The estimation of harmonics from nonlinear loads is the first step in a harmonic analysis and this may not be straight forward. Rotating machines are considered sources of harmonics because the windings are embedded in slots which are not perfectly sinusoidally distributed resulting in a distorted mmf.  Nonsinusoidal voltage applied to electric machines may cause overheating, pulsating torques or noise. In additional to cross the line applications, adjustable speed drive motors are fed from inverter that can produce significant voltage distortion. In induction motor, they can overheat due to the effects of harmonic currents, depending on their frequency, because of additional rotating magnetic fields in the motor. Harmonic produce harmonic fluxes in motors. The harmonic torques tends to rotate motor at different harmonic synchronous speeds. It can produce high frequency currents in rotor circuits. The data which collect from the site project will be inserting into Visualation Basic, VB. The parameters that will be state are voltage, current, frequency, time and total harmonic distortion. The reading will be collect with the different speed of motor. It causes to show how the speeds of motor produce harmonic distortion. Then it wills using the different type of starter motor there are Direct-On-Line, Auto-Transformer and Star-Delta.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Electric power distribution</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TK3091 .I89 2009 rs Bc.</subfield>
    <subfield code="p">0000037840</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 3295 | TK3091 .I89 2009 rs Bc.</subfield>
    <subfield code="p">0000037841</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">2677</subfield>
    <subfield code="d">2683</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5200*6500*9992</subfield>
  </datafield>
</record>