<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Automatic detection temperature transmitter for calibration process using thermocouple</title>
  </titleInfo>
  <titleInfo type="alternative">
    <title>Automatic detection temperature transmitter for calibration process using thermocouple</title>
  </titleInfo>
  <name type="personal">
    <namePart>Muhamad Farid A. Wahab</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">theses</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Kuantan, Pahang</placeTerm>
    </place>
    <publisher>UMP</publisher>
    <dateIssued>2010</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <form authority="gmd">computer file</form>
    <extent>xv, 84 p. : ill. (some col.) ; 30 cm. + 1 computer disc</extent>
  </physicalDescription>
  <abstract>The purpose of this project is to detect temperature for calibration process using type K thermocouple automatically. This project will be implementing using Visual Basic 2008 software to develop Graphic User Interface (GUI). The Type K thermocouple will be use as temperature sensor in calibration process. The implementation of proportional–integral–derivative controller (PID controller) will be monitor the automatic temperature set point and detection system. The Data Acquisition (DAQ) card will be use for interfacing process is to implementation of an automatic detection system for temperature measuring during calibration process. The accuracy of the measurement will be monitor besides the analysis of uncertainty and confidence limit</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Muhamad Farid A. Wahab</note>
  <note>Project paper (Bachelor of Electrical Engineering (Electronics)) -- Universiti Malaysia Pahang - 2010</note>
  <note>Bibliography : p. 66-67</note>
  <subject authority="lcsh">
    <topic>Temperature measurements</topic>
    <topic>Calibration</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Temperature measuring  instruments</topic>
    <topic>Calibration</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Thermocouples</topic>
  </subject>
  <identifier type="isbn">THE0005513(Local)</identifier>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">110719</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251114204456.0</recordChangeDate>
    <recordIdentifier source="KUKTEM">vtls000054894</recordIdentifier>
  </recordInfo>
</mods>