<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Automatic detection temperature transmitter for calibration process using RTD</title>
  </titleInfo>
  <titleInfo type="alternative">
    <title>Automatic detection temperature transmitter for calibration process using RTD</title>
  </titleInfo>
  <name type="personal">
    <namePart>Mustaqim Hazmi</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">theses</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Kuantan, Pahang</placeTerm>
    </place>
    <publisher>UMP</publisher>
    <dateIssued>2010</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <form authority="gmd">computer file</form>
    <extent>xvii, 83 p. : ill. (some col.) ; 30 cm. + 1 computer disc</extent>
  </physicalDescription>
  <abstract>The purpose for this project is to detect temperature for Calibration Process using Resistive Thermal Device (RTD) automatically. This project will be used Visual Basics (VB) programmed to develop Graphical User Interface (GUI). An RTD will be use as temperature sensor in this Calibration Process. The software and the temperature sensor will be interfaced by using a Data Acquisition (DAQ) card. Proportional–Integral–Derivative (PID) controller will be purpose for automatic detection for temperature system. The expected result for this project is an automatic detection system for temperature measure during the Calibration Process. The accuracy of the measurement will be monitor beside the analysis of uncertainty and confidence limit</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Mustaqim Hazmi</note>
  <note>Project paper (Bachelor of Electrical Engineering (Electronics)) -- Universiti Malaysia Pahang - 2010</note>
  <note>Bibliography : p. 61-62</note>
  <subject authority="lcsh">
    <topic>Temperature measurements</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Temperature measuring  instruments</topic>
    <topic>Calibration</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Resistance thermometers</topic>
    <topic>Calibration</topic>
  </subject>
  <identifier type="isbn">THE0005516(Local)</identifier>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">110720</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251114204503.0</recordChangeDate>
    <recordIdentifier source="KUKTEM">vtls000054907</recordIdentifier>
  </recordInfo>
</mods>
