<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02971nam a2200265 a 4500</leader>
  <controlfield tag="001">vtls000075695</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204548.0</controlfield>
  <controlfield tag="008">131022t2012    my da  f abm  000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0006026(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905151147</subfield>
    <subfield code="b">aida</subfield>
    <subfield code="y">201310221013</subfield>
    <subfield code="z">nabilah</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TH7687.8 .Z36 2012 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Mohd Zamri Mohd Kama</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="2">
    <subfield code="a">A study of humidity effect toward the quality of air from air conditioning system /</subfield>
    <subfield code="c">Mohd Zamri Mohd Kama</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2012</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xvii, 73 p. :</subfield>
    <subfield code="b">ill. ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 CD-ROM</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Mechanical Engineering (Automotive)) -- Universiti Malaysia Pahang &#x2013; 2012</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Bibliography : p. 65-66</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">This thesis is about study of humidity effect towards quality of air using air conditioning unit at Mechanical Engineering Faculty (FKM) University Malaysia Pahang (UMP). Humidity is the quality of how much water or moisture content in the air. This project is to analyze the effect of dehumidification towards quality of air from air conditioning unit. The dehumidification method is using heater which is supplied before and after the evaporator. Variable speed of air flow is conducted to determine the effect of air speed toward dehumidification. Analysis is done by giving different value of air speed and different humidity. Experiment is conducted using air conditioning unit at thermodynamic laboratory which 24 experiments were done by giving different value of fan speed and humidity. Effect of pre-heater and re-heater also being monitored by varies the situation inside the air conditioning duct by switch on and off both of the heaters. After each experiment is being conducted, the quality of air at the exit is monitored and plotted on Psychrometric chart. Standard ASHRAE thermal comfort zone is used to determine the optimum temperature and humidity for thermal comfort. Various graphs is plotted and to determine the effect of humidification toward various parameters such as Coefficient of Performance (COP) of refrigerant, point temperatures, amount of heat being transferred and humidity. From the results, by increasing the velocity will help to make the environment become more comfortable. Secondly, increasing air velocity flow through evaporator increase its heat transfer and be calculated using energy balance equation. Besides that, from the experiment pre-heater and re-heater help to adjust the humidity and temperature at each point. Then, usage of humidifier causing the temperature and humidity to became further away from thermal comfort zone. Thus without using the humidifier, the quality of air from air conditioning unit FKM UMP can be improved.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Air conditioning</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Humidity</subfield>
    <subfield code="x">Control</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Air quality</subfield>
    <subfield code="x">Analysis</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TH7687.8 .Z36 2012 rs Bc.</subfield>
    <subfield code="p">0000076167</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 7345 | TH7687.8 .Z36 2012 rs Bc.</subfield>
    <subfield code="p">0000076168</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">4153</subfield>
    <subfield code="d">4159</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5020*5040*5200*6500*6501*6502*9992</subfield>
  </datafield>
</record>
