<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Biomethanation of palm oil mill effluent (pome) by ultrasonic membrane anaerobic system (umas) using pome as substrate</title>
  </titleInfo>
  <name type="personal">
    <namePart>Nuri ‘Adilah Nashrulmillah Idris</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <typeOfResource manuscript="yes">text</typeOfResource>
  <genre authority="marc">theses</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Kuantan, Pahang</placeTerm>
    </place>
    <publisher>UMP</publisher>
    <dateIssued>2014</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>xiv, 62 p. : ill. ; 30 cm. + 1 CD-ROM</extent>
  </physicalDescription>
  <abstract>The direct discharge of the Palm Oil Mill Effluent (POME) wastewater causes serious  environmental pollution due to its high chemical oxygen demand (COD), total  suspended solid (TSS) and biological oxygen demand (BOD). The conventional ways  for POME wastewater treatment have both economical and environmental  disadvantages. In this study, the potential of ultrasonic-assisted membrane anaerobic  system (UMAS) was evaluated as alternative and cost effective method for treating  POME wastewater to avoid fouling. The UMAS treatment efficiency was greatly  improved by UMAS introduction. The membrane fouling and polarization at the  membrane surface was significantly reduced. This research had proved that UMAS is  the effective way to treat POME. The removal efficiency of COD was 95% with HRT  of 6 days. The BOD removal efficiency was 71.59% while TSS removal rate was from  91 to 99.5%.The methane gas production efficiency was 94.14%.The UMAS treatment  efficiency was greatly improved by UMAS introduction. The membrane fouling and  polarization at the membrane surface was significantly reduced. This research had  achieved the objectives by resolve the problem statement</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Nuri ‘Adilah Nashrulmillah Idris</note>
  <note>Faculty of Chemical &amp; Natural Resources Engineering</note>
  <note>Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2014</note>
  <note>Bibliography : p. 61</note>
  <subject authority="lcsh">
    <topic>Membrane reactors</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Bioreactors</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Palm oil</topic>
  </subject>
  <identifier type="isbn">THE0004404(Local)</identifier>
  <identifier type="uri">http://ecollib.ump.edu.my/18285/</identifier>
  <location>
    <url>http://ecollib.ump.edu.my/18285/</url>
  </location>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">150114</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251117113240.0</recordChangeDate>
    <recordIdentifier source="KUKTEM">vtls000084861</recordIdentifier>
  </recordInfo>
</mods>
