<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02296nam a2200241 a 4500</leader>
  <controlfield tag="001">vtls000025650</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204343.0</controlfield>
  <controlfield tag="008">080324t2007    my     f m    000 0 eng|d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0006903(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201906131021</subfield>
    <subfield code="b">aida</subfield>
    <subfield code="c">201107132002</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141420</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141352</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="y">200803241238</subfield>
    <subfield code="z">kam</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TK7868.P8 S53 2007 rs Thesis</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Mohd Shazni Saringat</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Digital thermometer via power supply /</subfield>
    <subfield code="c">Mohd Shazni Saringat</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">Digital thermometer via power supply</subfield>
    <subfield code="h">[electronic resource]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2007</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">84 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Electrical Engineering (Control and Instrumentation)) - Universiti Malaysia Pahang - 2007</subfield>
  </datafield>
  <datafield tag="520" ind1="1" ind2=" ">
    <subfield code="a">Nowadays, wide variety of sensing system is available in the market. Nearly all kinds of models consists several sensing system for its costumers pleasure and comfort. Sensors involving the fuel level, water battery level and temperature are a few of the systems that are famously used nowadays. These sensors are considered vital, because it involves many aspects, especially for a system to function perfectly. Besides, sensors are also use to give important readings, which resembles different aspects, such as safety, and etc. of all the sensing systems, the temperature is considered as the most important element of sensing that is widely used in the world. This receiver system will consist of amplifier, filter, multiplexer, latch and decoder for the hardware part. The output of the receiver will be displayed at the 7 segment at the end of the receiver circuit. The data (frequency pulse) from the power supply will be insulated by capacitors and inductors and the amplifier. Then, the data will be filtered and divided by 10. Lastly, after the process of dividing is complete, the data will go through the multiplexer and then displayed. The objective of this project is to build a receiver device that receives the temperature reading from the frequency pulse at the transformer (power supply).  -Author</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Pulse circuits</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TK7868.P8 S53 2007 rs Thesis</subfield>
    <subfield code="p">0000029388</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 2663 | TK7868.P8 S53 2007 rs Thesis</subfield>
    <subfield code="p">0000029389</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">564</subfield>
    <subfield code="d">570</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5200*6500*9992</subfield>
  </datafield>
</record>
