01796ntm a2200229 a 4500001001400000003000700014005001700021008004100038020002200079040000800101100002600109245016200135260003400297300004500331500005600376502009200432504002800524520091400552650002401466650001601490856006001506vtls000084608KUKTEM20251117113249.0141222t2014 my a f m 000 0 eng d aTHE0004437(Local) aUMP0 aNik Syahira Nik Alias10aEffect of the time taken on the performance of fabricated gas–solid fluidized bed column for the separation of rare earth elements /cNik Syahira Nik Alias aKuantan, Pahang :bUMP,c2014 axvi, 52 p. :bill. ;c30 cm. +e1 CD-ROM aFaculty of Chemical & Natural Resources Engineering aProject paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2014 aBibliography : p. 48-523 aA gas–solid fluidized bed separator used for the separation of rare earth elements (REEs) from printed circuit board was design and fabricated. In this work, the effect of time taken on the performance of the fabricated gas-solid fluidized bed column for the separation of rare earth elements was study. Waste from electronic devices was grinded to powder forms with the particles sized less than 1.0 μm were used in this study. Beds column with different heights of sampling port were analyzed at 10 cm, 20 cm, and 30 cm while the air pressure was 15 psi, 20 psi and 25 psi were tried in this investigation. The rare earth elements were subsequently analyzed by float–sink testing. The results showed the weight percent of the fine powder increases with increasing the time taken for collecting the sample. However, the separation density decreased with increasing the sampling port height of the column 0aMembrane separation 0aFabrication40uhttp://ecollib.ump.edu.my/9670/zAccess in library only