<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02253ntm a2200277 a 4500</leader>
  <controlfield tag="001">vtls000091134</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251117113309.0</controlfield>
  <controlfield tag="008">150903t2015    my dao f m    000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0003863(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905161532</subfield>
    <subfield code="b">shah</subfield>
    <subfield code="c">201711281339</subfield>
    <subfield code="d">saini</subfield>
    <subfield code="y">201509031247</subfield>
    <subfield code="z">huda</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TP156.A35 W66 2015 r Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Wong Jing Zhi, Kelvin</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Effects of polyvinylpyrrolidone additive on the performance of hollow fiber ion exchanger mixed matrix membrane for copper removal /</subfield>
    <subfield code="c">Kelvin Wong Jing Zhi</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2015</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xvi, 86 p. :</subfield>
    <subfield code="c">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 CD-ROM</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Faculty of Chemical &amp; Natural Resources Engineering</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang - 2015</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Bibliography : p. 54-59</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">The existence of copper in the environment is a concern due to the acute and long term toxicity. With the advantages of lower capital cost, easy operation process and high copper removal percentage, ion exchange technology offers the best treatment for copper removal but it has a drawback where it will cause a vast drop in pressure. In order to overcome this limitation, an ion exchanger mixed matrix membrane was produced in this study. Amberlite IR 120H cation exchanger was incorporated in the polyethersulfone (PES) based polymer solution. The effect of polyvinylpyrrolidone (PVP) pore forming additive in the PES dope solution was studied in the range of 0 to 10wt%. The hollow fiber membrane was synthesized using dry-wet spinning procedure. The pore structure of the membrane was characterized using Scanning Electron Microscope (SEM) and was found more porous as the concentration of PVP increases. The permeability was also increased as the concentration of PVP increases. The optimum concentration of PVP for the removal of copper is between 3wt% and 5wt%.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Adsorption</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Sewage</subfield>
    <subfield code="x">Purification</subfield>
    <subfield code="x">Heavy metal removal</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
    <subfield code="u">http://ecollib.ump.edu.my/id/eprint/25849</subfield>
    <subfield code="z">Access in library only  </subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TP156.A35 W66 2015 r Bc.</subfield>
    <subfield code="p">0000100582</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">6</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 8948 | TP156.A35 W66 2015 r Bc.</subfield>
    <subfield code="p">0000100583</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">6291</subfield>
    <subfield code="d">6297</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5000*5020*5040*5200*6500*6501*8560*9992</subfield>
  </datafield>
</record>
