<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>03824nam a2200265 a 4500</leader>
  <controlfield tag="001">vtls000045061</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251117113318.0</controlfield>
  <controlfield tag="008">100129t2009    my a   f m    000 0 eng&#x89;d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0002401(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905271259</subfield>
    <subfield code="b">shamsul</subfield>
    <subfield code="c">201107132306</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">201002091048</subfield>
    <subfield code="d">ida</subfield>
    <subfield code="c">201001291649</subfield>
    <subfield code="d">ida</subfield>
    <subfield code="y">201001291648</subfield>
    <subfield code="z">ida</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TA357. A45 2008 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Muhammad Aminuddin Abd Rahman</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Application of fluent tp predict combustion performance for pure propane/</subfield>
    <subfield code="c">Muhammad Aminuddin Abd Rahman</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">Application of fluent tp predict combustion performance for pure propane</subfield>
    <subfield code="h">[electronic resource]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2008</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">70 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of of Chemical engineering (Gas Technology)) -- Universiti Malaysia Pahang - 2009</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Bibliography : p. 56 - 57</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Computational Fluid Dynamic (CFD) is a used tool in optimizing propane burner for emissions issues and to study combustions  characteristics of flame temperature and flame velocity in furnace system. Using CFD simulation, cost and time can reduce in development new furnace and burner. Studies are aimed at improving combustion performance with reduce pollutant emissions. Also focus on the combustion patterns in the form of measured contours of temperature and species concentrations. Pure propane used as a fuel in this research. Before doing computer simulation, several experiments  were running first. Only the best data will choose. This data is use in boundary setting when doing simulation process. In experimental work, practical combustor C492 gas burner is used. The data from the experimental work will analyze and compare to get a constant and stable data. For simulation work 2D design for practical combustor was done in Gambit software. In this software, the design was mesh and export to Fluent 6.3. Fluent 6.3 is one of CFD software that uses to study combustion and flow characteristics. The result from experimental work and computer simulation then compared. The comparison shows in the Table 4.2 in term of percentage differences. Best result depends on small percentage between this two data.-Author-Computational Fluid Dynamic (CFD) is a used tool in optimizing propane burner for emissions issues and to study combustions  characteristics of flame temperature and flame velocity in furnace system. Using CFD simulation, cost and time can reduce in development new furnace and burner. Studies are aimed at improving combustion performance with reduce pollutant emissions. Also focus on the combustion patterns in the form of measured contours of temperature and species concentrations. Pure propane used as a fuel in this research. Before doing computer simulation, several experiments  were running first. Only the best data will choose. This data is use in boundary setting when doing simulation process. In experimental work, practical combustor C492 gas burner is used. The data from the experimental work will analyze and compare to get a constant and stable data. For simulation work 2D design for practical combustor was done in Gambit software. In this software, the design was mesh and export to Fluent 6.3. Fluent 6.3 is one of CFD software that uses to study combustion and flow characteristics. The result from experimental work and computer simulation then compared. The comparison shows in the Table 4.2 in term of percentage differences. Best result depends on small percentage between this two data.-Author-</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Fluid dynamics</subfield>
    <subfield code="x">Computer simulation</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Fluid dynamics</subfield>
    <subfield code="x">Data processing</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TA357. A45 2008 rs Bc.</subfield>
    <subfield code="p">0000042871</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD3963 | TA357. A45 2008 rs Bc.</subfield>
    <subfield code="p">0000042872</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">6545</subfield>
    <subfield code="d">6551</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5040*5200*6500*6501*9992</subfield>
  </datafield>
</record>