<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Behaviour of oil palm shell reinforced concrete beam partly replaced by palm oil fuel ash</title>
  </titleInfo>
  <name type="personal">
    <namePart>Mohd Asmawi Md Desa</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <typeOfResource manuscript="yes">text</typeOfResource>
  <genre authority="marc">theses</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Kuantan, Pahang</placeTerm>
    </place>
    <publisher>UMP</publisher>
    <dateIssued>2016</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>xii, 38 p. : ill. (some col.) ; 30 cm. + 1 CD-ROM</extent>
  </physicalDescription>
  <abstract>In Malaysia, issue of natural contamination coming about because of transfer of Palm Oil Fuel Ash (POFA) which is a by-item from palm oil mill has started exploration to consolidate this waste in Oil Palm Shell (OPS) lightweight concrete structural. The current investigates the behaviour of oil palm shell reinforced concrete beam partly replaced by palm oil fuel ash. All mixes were casted in total of 4 reinforced concrete beam and 24 cubes with OPS RC mixes were producing by replaced 20% of POFA on cement, sand and aggregates were fabricated and tested. The flexural test and compressive test is conducted in accordance to BS EN 12390 – 3 and BS EN 12390 – 5 at the age of 7 and 28 days. The Data presented include the load – deflection curves, ductility, compressive strength and cracking pattern. From the result, it was observed that mixes with replaced POFA on cement would enhance the strength of concrete and from the flexural test shows that with replacement on cement, the ductility of beam is better than others replacement.</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Mohd Asmawi Md Desa</note>
  <note>Faculty of Civil Engineering and Earth Resources</note>
  <note>Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2016</note>
  <note>Bibliography : p. 35-38</note>
  <subject authority="lcsh">
    <name type="corporate">
      <namePart>Faculty of Civil Engineering and Earth Resources</namePart>
    </name>
    <topic>Dissertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Universities and Colleges</topic>
    <topic>Dissertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Theses</topic>
  </subject>
  <identifier type="isbn">THE0000311(Local)</identifier>
  <identifier type="uri">http://ecollib.ump.edu.my/id/eprint/3932</identifier>
  <location>
    <url>http://ecollib.ump.edu.my/id/eprint/3932</url>
  </location>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">161123</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251117113336.0</recordChangeDate>
    <recordIdentifier source="KUKTEM">vtls000098145</recordIdentifier>
  </recordInfo>
</mods>
