<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02260nam a2200253 a 4500</leader>
  <controlfield tag="001">vtls000045128</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204354.0</controlfield>
  <controlfield tag="008">100218t2009    my a   f m    000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0004281(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905161359</subfield>
    <subfield code="b">farhana</subfield>
    <subfield code="c">201107132307</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="y">201002181152</subfield>
    <subfield code="z">kam</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TP242 .F37 2009 rs Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Farhana Hasbullah</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Permeability and selectivity study of polysulfone membrane for gas separation /</subfield>
    <subfield code="c">Farhana Binti Hasbullah</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">Permeability and selectivity study of polysulfone membrane for gas separation</subfield>
    <subfield code="h">[electronic resource]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2009</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">60 p. :</subfield>
    <subfield code="b">ill. (some col.) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Chemical Engineering (Gas Technology)) -- Universiti Malaysia Pahang - 2009</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Polysulfone (PSU) membrane is one of the economical and potential membranes to be used in gas separation process. Polysulfone flat sheet membrane were fabricated from 22.0 wt% polysulfone, 31.8 wt% N,N-dimethylformamide, 31.8 wt% tetrahydofuran and 14.4 wt% ethanol using dry/wet phase inversion process. Eight different samples were tested. The permeability of the membranes were tested using the gas permeation unit with pressure of 1.5-2.5 bar and were tested with CO2, CH4, N2 and also O2. Among all these eight types of membrane tested, several show that the behavior of polysulfone membrane to permeate CO2 relies on the treatment that the membranes undergo and the temperature of the coagulation bath. Thus, the most excellent value of permeability for CO2 among eight types of membranes tested was 4.98 x 10-3 cm3/cm2.s.cmHg which was PSU membrane immersed in a 4&#xB0;C coagulation bath and treated with polydimethylsiloxane (PDMS) as a coating agent with the selectivity value of 1.36.From the data and result collected it is to be proved that temperature of coagulation bath and also the coating agent for membrane treatment play a major role in affecting PSU membrane permeability and selectivity as a whole.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Gases</subfield>
    <subfield code="x">Separation</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Separation (Technology)</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TP242 .F37 2009 rs Bc.</subfield>
    <subfield code="p">0000042869</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 3962 | TP242 .F37 2009 rs Bc.</subfield>
    <subfield code="p">0000042870</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">882</subfield>
    <subfield code="d">888</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5200*6500*6501*9992</subfield>
  </datafield>
</record>
