    <title>The effect of perforations on built-up open section cold-formed steel beam</title>
  </titleInfo>
  <name type="personal">
    <namePart>Siti Sharina Baharom</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
    <role>
      <roleTerm type="text">author.</roleTerm>
    </role>
  </name>
  <typeOfResource manuscript="yes">text</typeOfResource>
  <genre authority="marc">theses</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <dateIssued encoding="marc">2018</dateIssued>
    <copyrightDate encoding="marc">2018</copyrightDate>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>x, 49 pages : illustrations ; 30 cm. + 1 CD-ROM</extent>
  </physicalDescription>
  <abstract>This paper presents the study of the effect on built-up open section when receiving load in term of flexural behavior (failure mode) and the ultimate load with the present of web perforations. In steel production, there are two types of structural members which are hotrolled steel and the other one is cold-formed steel. In detail, cold-formed steel is pressed at significantly cooler temperatures and often even room temperature. Hot-rolled steel is heated above the metal recrystallization temperature (around 1700° F or higher) to make it easier to bend the metal into specific shape. This experiment is involving the beam test on several specimens  focuses on built-up open section steel with various position of webopening on the beam. Each specimen have 1600  mm length and different position  of webperforations. The shape of openings used are circle and the size are keep constant that is 20 mm diameter to ensure the consistency in the result making. The ultimate load strength of the cold-formed steel section and failure modes differs depend on the position of the openings and the number of the opening, where the conclusions are make on the basis of the  comparisons  between  the  positions  of  openings.  The  value  of  displacement  was measured by using the transducer which placed at the middle point below the beam. The load – displacement graph was plotted after the result is obtained.</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Siti Sharina Baharom</note>
  <note>Faculty of Civil Engineering and Earth Resources</note>
  <note>Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2018</note>
  <note>Includes bibliographical references</note>
  <subject authority="lcsh">
    <name type="corporate">
      <namePart>Faculty of Civil Engineering and Earth Resources</namePart>
    </name>
    <topic>Disertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Universities and colleges</topic>
    <topic>Disertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Theses</topic>
  </subject>
  <identifier type="isbn">THE0008307(Local)</identifier>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">191017</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251125105408.0</recordChangeDate>
    <languageOfCataloging>
      <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
    </languageOfCataloging>
  </recordInfo>
</mods>