<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>03762ntm a2200361 i 4500</leader>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="8">REF</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="c">REF</subfield>
    <subfield code="d">2019-11-07</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">FKASA .Y34 2018 r Bc.</subfield>
    <subfield code="p">0000127220</subfield>
    <subfield code="r">2020-09-30 00:00:00</subfield>
    <subfield code="w">2019-11-07</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">REF</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="c">REF</subfield>
    <subfield code="d">2019-11-07</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD12105</subfield>
    <subfield code="p">0000127221</subfield>
    <subfield code="r">2020-11-20 00:00:00</subfield>
    <subfield code="w">2019-11-07</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">91090</subfield>
    <subfield code="d">91096</subfield>
  </datafield>
  <controlfield tag="003">MY-KuUP</controlfield>
  <controlfield tag="005">20251125105421.0</controlfield>
  <controlfield tag="006">t||||fr|||| 000 0 </controlfield>
  <controlfield tag="007">ta</controlfield>
  <controlfield tag="008">191107t20182018my a|||frm||| 000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0008327(Local)</subfield>
    <subfield code="q">hardback</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
    <subfield code="b">eng</subfield>
    <subfield code="c">UMP</subfield>
    <subfield code="e">rda</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">FKASA .Y34 2018 r Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Al-Amri, Mohammed Yahya ,</subfield>
    <subfield code="e">author.</subfield>
  </datafield>
  <datafield tag="245" ind1="4" ind2="0">
    <subfield code="a">The mechanical properties of concrete containing palm oil clinker as fine aggregate replacement /</subfield>
    <subfield code="c">Mohammed Yahya Al-Amri</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="1">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2018</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="1">
    <subfield code="c">&#xA9; 2018</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xiv, 58 pages :</subfield>
    <subfield code="b">illustrations (some color) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 CD-ROM</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="a">text</subfield>
    <subfield code="2">rdacontent</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="a">unmediated</subfield>
    <subfield code="2">rdamedia</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="a">computer</subfield>
    <subfield code="2">rdamedia</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="a">volume</subfield>
    <subfield code="2">rdacarrier</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="a">computer disc</subfield>
    <subfield code="2">rdacarrier</subfield>
  </datafield>
  <datafield tag="347" ind1=" " ind2=" ">
    <subfield code="a">text file</subfield>
    <subfield code="b">PDF</subfield>
    <subfield code="2">rda</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Faculty of Civil Engineering and Earth Resources</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang &#x2013; 2018</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Includes bibliographical references</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">The  increasing  sand  mining  activity  to  due  to  growth  of  construction  industry  in Malaysia, demand toward construction material. and the escalation of palm oil clinker(POC)  disposal from Malaysian palm oil industry  have  caused negative impact to the environment  quality.  Uncontrolled  river  sand  mining  activity  can  cause  ecological imbalance  such  as  destruction  of  flora  and  fauna,  river  bank  erosion  and  water pollution. The dumping of POC in growing quantity throughout the years  worsen the environmental pollution, consumes larger disposal area and increases the cost spent by the palm oil mill in managing the waste.  The main aim of this research is to study the mechanical  performance  of  concrete  containing  palm  oil  clinker  as  partial  sand replacement. The objectives of this study are  to  investigate the effect of palm oil  clinkeras partial sand replacement on workability, compressive,  flexural strength  and water absorption  of concrete. Two mixes  were prepared in this research which are control mix and  modified  mix.  The  slump  test  decreases  as  the  percentage  of  palm  oil  clinkercontent replaced becomes higher.  Reduction  of palm oil clinker  in the concrete mix workability is probably due to the higher rate of water absorption of this fine aggregate which possess higher porosity as compared to natural sand.  The presence of POC  as partial  replacement  of  sand  in  concrete  would  reduce  the  compressive  strength  of concrete. Concrete containing 20% of POC as partial sand replacement recorded that it achieved about 90% of the strength of the control concrete. It is the highest among the other replacement percentage of POC.  The presence of POC as partial replacement of sand in concrete would affect the flexural strength. However, the sample containing 20% of POC had the highest flexural strength compared to 10%, 30% and 40% of POC replacements.  The concrete containing 20% of POC as partial sand replacement have 87% of the flexural strength of the control concrete.  POC as partial sand replacement in  concrete  production  would  increase  the  water  absorption  value  of  concrete.  The percentage  of  water  absorption  of  the  concrete  increase  with  the  increment  in  the amount of POC in concrete.  Conclusively, 20% of POC  is the  optimum  amount to be compared among other replacement to be used as partial sand replacement to produceconcrete.</subfield>
  </datafield>
  <datafield tag="610" ind1="2" ind2="0">
    <subfield code="a">Faculty of Civil Engineering and Earth Resources</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Universities and colleges</subfield>
    <subfield code="x">Disertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="x">Theses</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">lcc</subfield>
    <subfield code="c">PSM</subfield>
  </datafield>
</record>
