<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Influence of elevated temperature on properties of oil palm shell (OPS) lightweight concrete containing coal bottom ash as partial sand replacement</title>
  </titleInfo>
  <name type="personal">
    <namePart>Siti Nurdiana Jamil</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
    <role>
      <roleTerm type="text">author.</roleTerm>
    </role>
  </name>
  <typeOfResource manuscript="yes">text</typeOfResource>
  <genre authority="marc">abstract or summary</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <dateIssued encoding="marc">2019</dateIssued>
    <copyrightDate encoding="marc">2019</copyrightDate>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>xiii, 51 pages : illustrations ; 30 cm. + 1 CD-ROM</extent>
  </physicalDescription>
  <abstract>Excessive waste product disposed from oil palm mills and coal combustion plants results in environmental pollution and landfill problem. Hence, the use of waste materials as a replacement for concrete producing materials will reduce pollution. An investigation on the residual compressive strength of concrete containing coal ash (CBA) after being exposed to high temperatures and the cooling process was performed. The purpose of this study is to investigate the effect of temperature rise on physical properties, mass loss and residual strength of concrete specimens. Oil palm shell lightweight aggregate concrete and the specimen were exposed to various temperature levels of 100oC, 300 oC, 500 oC, and 800 oC. OPS concrete containing 0%, 10%, 20%, and 30% of CBA as partial sand replacement were used. Two cooling systems that is air cooling at room temperature and water cooling system with water spray using rubber pipe. The physical changes, mass loss and strength loss of concrete after exposed to high temperature were monitored. The performance of concrete specimens was found to be higher in concrete containing CBA than normal concrete. Mass loss increases due to temperature increases. The strength of the concrete decreases due to the temperature increases.</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Siti Nurdiana Jamil</note>
  <note>Faculty of Civil Engineering and Earth Resources</note>
  <note>Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2019</note>
  <note>Includes bibliographical references</note>
  <subject authority="lcsh">
    <name type="corporate">
      <namePart>Faculty of Civil Engineering and Earth Resources</namePart>
    </name>
    <topic>Disertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Universities and colleges</topic>
    <topic>Disertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Theses</topic>
  </subject>
  <identifier type="isbn">THE0008710(Local)</identifier>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">200708</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251125105550.0</recordChangeDate>
    <languageOfCataloging>
      <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
    </languageOfCataloging>
  </recordInfo>
</mods>
