<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>03798ntm a2200373 i 4500</leader>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">6</subfield>
    <subfield code="8">REF</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="c">REF</subfield>
    <subfield code="d">2020-07-20</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">FKASA .A955 2019 r Bc.</subfield>
    <subfield code="p">T000000884</subfield>
    <subfield code="r">2020-07-20 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2020-07-20</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">REF</subfield>
    <subfield code="a">10000</subfield>
    <subfield code="b">10000</subfield>
    <subfield code="d">2020-07-20</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD12669</subfield>
    <subfield code="p">T000000885</subfield>
    <subfield code="r">2021-03-11 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2020-07-20</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">92690</subfield>
    <subfield code="d">92696</subfield>
  </datafield>
  <controlfield tag="003">MY-KuUP</controlfield>
  <controlfield tag="005">20251125105602.0</controlfield>
  <controlfield tag="006">t||||fr|||| 000 0 </controlfield>
  <controlfield tag="007">ta</controlfield>
  <controlfield tag="008">200720t20192019my ab||fram|| 000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0008795(Local)</subfield>
    <subfield code="q">hardback</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
    <subfield code="b">eng</subfield>
    <subfield code="c">UMP</subfield>
    <subfield code="e">rda</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">FKASA .A955 2019 r Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Azlina Nordin,</subfield>
    <subfield code="e">author.</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Seismic design for reinforced concrete office building influenced by concrete grade and level of seismicity /</subfield>
    <subfield code="c">Azlina Nordin</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="1">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2019</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="4">
    <subfield code="c">&#xA9; 2019</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xii, 59 pages :</subfield>
    <subfield code="b">illustrations, maps (some color) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 CD-ROM</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="a">text</subfield>
    <subfield code="2">rdacontent</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="a">text</subfield>
    <subfield code="2">rdacontent</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="a">unmediated</subfield>
    <subfield code="2">rdamedia</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="a">computer</subfield>
    <subfield code="2">rdamedia</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="a">volume</subfield>
    <subfield code="2">rdacarrier</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="a">computer disc</subfield>
    <subfield code="2">rdacarrier</subfield>
  </datafield>
  <datafield tag="347" ind1=" " ind2=" ">
    <subfield code="a">text file</subfield>
    <subfield code="b">PDF</subfield>
    <subfield code="2">rda</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Faculty of Civil Engineering and Earth Resources</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang &#x2013; 2019</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Includes bibliographical references</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Earthquake is a natural disaster that may lead to collapsing of building. Office building is a place the employee do their work, when earthquake happened, the building will not be able to withstand the earthquake which may be dangerous to people. So, in order to be a safe place, the building must withstand the disaster such as earthquake. Malaysia is considered to have a low seismicity profile but more evidences are showing that early assumption Malaysia is free from earthquake are misleading. The earthquake on 2004 Indian-Ocean earthquake with magnitude 9.1 which killed 68 lives in Malaysia and thousands others in Indonesia, Sri Lanka and Thailand. Therefore, this work will focus on study the effect of seismic design on the weight of steel reinforcement and volume of concrete used for office building. The first objectives is to study the effect on magnitude of PGA on the amount of steel reinforcement. The second objectives is to study the effect on grade of concrete on the amount of steel reinforcement. And the third objectives for this research is to study the influence of PGA and grade of concrete on cost estimation. In the total of 16 models of reinforced concrete office building with number of 3 and 6 storeys will be used in this analysis. The models will be design for two different grade of concrete which are G25 and G30. The value of PGA will be fixed as 0.03g, 0.09g and 0.15g. This study only considered the ductility class medium and soil type D. Tekla structure software will be used for analysis and designed based on Eurocode 8 (2004). The comparison will be made in term of amount of steel required as 1m3 of concrete for every model. For different magnitude of PGA, the result shows that the percentage difference of steel reinforcement required to non-seismic model of 3-storey and 6-storey office building had increased from 2%, 14% and 56% and 7%, 49% and 162% for reference peak ground acceleration, agR = 0.03g, 0.09g and 0.15g respectively. While for different value of grade of concrete, the result shows that the percentage difference of steel reinforcement required to non-seismic model of 3-storey and 6-storey office building had decrease from 36% to 56% and 162% to 139% respectively according to different grade of concrete. Thus, magnitude of PGA and concrete grade of structure give significant effect to overall amount of steel reinforcement required. Hence, it should be considered in designing a seismic building.</subfield>
  </datafield>
  <datafield tag="610" ind1="2" ind2="0">
    <subfield code="a">Faculty of Civil Engineering and Earth Resources</subfield>
    <subfield code="x">Disertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Universities and colleges</subfield>
    <subfield code="x">Disertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Theses</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">lcc</subfield>
    <subfield code="c">PSM</subfield>
  </datafield>
</record>
