<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02155nam a2200253 a 4500</leader>
  <controlfield tag="001">vtls000037643</controlfield>
  <controlfield tag="003">KUKTEM</controlfield>
  <controlfield tag="005">20251114204356.0</controlfield>
  <controlfield tag="008">090611t2008    my a   f m    000 0 eng|d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0006776(Local)</subfield>
  </datafield>
  <datafield tag="039" ind1=" " ind2="9">
    <subfield code="a">201905290937</subfield>
    <subfield code="b">amirul</subfield>
    <subfield code="c">201107132136</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141628</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="c">200908141601</subfield>
    <subfield code="d">VLOAD</subfield>
    <subfield code="y">200906111436</subfield>
    <subfield code="z">ida84</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">TK2851 .S53 2008 rs  Bc.</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Mohd Shakirun Naim Md Isa</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">PC based SMPS protection /</subfield>
    <subfield code="c">Mohd Shakirun Naim Md Isa</subfield>
  </datafield>
  <datafield tag="246" ind1="3" ind2=" ">
    <subfield code="a">PC based SMPS protection</subfield>
    <subfield code="h">[electronic resource]</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2008</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">78 p. :</subfield>
    <subfield code="b">ill. (some col.) ,</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 computer disc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Project paper (Bachelor of Electrical Engineering (Power systems)) -- Universiti Malaysia Pahang - 2008</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">The PC Based SMPS Protection is a system that preventing the electrical equipment    from damage due to overvoltage and overcurrent. This project is able to replace the function of fuse, increase efficiency of protection and reduce maintenance cost. This project basically focus on the designing the system include sensing elements, amplifier circuit and software (VB.net). When overvoltage or overcurent occurred the system is automatically turn-off the supply to the load by disable the PWM signal to the SMPS. In addition, the warning message is activated due to this problem to alerts the user from the problem occurred. Thus, the load or electrical components are safe from damage of overvoltage and overcurrent. The system detects the overvoltage and overcurrent from sensing circuit that using the shunt resistor concepts. The system used DAQ (USB-4716) as the data acquisition to convert the analogue to digital data (ADC) for data logging and integrated with the VB.net programming language to communicate with user. Through PC, user can monitor the status of the current and voltage to the load or electrical components.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Electric apparatus and appliances</subfield>
    <subfield code="x">Protection</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Voltage regulators</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">TK2851 .S53 2008 rs  Bc.</subfield>
    <subfield code="p">0000037412</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">1</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="d">2019-09-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD 3270 | TK2851 .S53 2008 rs  Bc.</subfield>
    <subfield code="p">0000037413</subfield>
    <subfield code="r">2019-09-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2019-09-04</subfield>
    <subfield code="y">PSM</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VIRTUA40</subfield>
    <subfield code="c">936</subfield>
    <subfield code="d">942</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="a">VTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5200*6500*6501*9992</subfield>
  </datafield>
</record>