<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Thermal fatigue of laser modified tool steels mould surface at high temperature</title>
  </titleInfo>
  <name type="personal">
    <namePart>Annie Lau Sheng</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
    <role>
      <roleTerm type="text">author.</roleTerm>
    </role>
  </name>
  <typeOfResource manuscript="yes">text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <dateIssued encoding="marc">2020</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>xiv, 93 pages : illustrations (some color) ; 30 cm. + 1 CD ROM</extent>
  </physicalDescription>
  <abstract>In die casting environment, tool steel service life decrease due to the  oxidation, erosion,  corrosion  and thermal fatigue  cracks which occur on the die surface that cause production  downtime and losses.  Thermal fatigue cracks is a significant failure which is around 70%  in die casting dies. In order to reduce the thermal fatigue cracks, the surface roughness  (SR) and hardness of laser modified samples have to be tailored. In this study, the effect  of laser surface modification parameters on SR and hardness was investigated to reduce  the  thermal  fatigue  crack.  The  hardness  and  microstructure  of  laser  modified  and  asreceived  AISI  H13  tool  steels  that  subjected  to  the  thermal  fatigue  test  were  also  investigated. First, a full factorial design of experiment (DOE) was developed. The three  factors were peak power (W), pulse repetition frequency (PRF) and overlap rate (%) with  the range  of 1500-1900W, 40-60Hz and 10-30% respectively.  Then,  fiber laser system  with pulse mode was applied on the surface of AISI H13 tool steel. The SR and hardness  of all the laser modified samples  were  then  measured.  After that, the as-received AISI  H13 and selected laser  modified samples were  used to conduct  a  thermal fatigue test  which  involve  cyclic  immersion  test.  The  thermal  fatigue  test  was  conducted  by  continuously heating the samples in molten aluminium and cooling in  a  water bath at a  respective  temperature  range  of  850-900  °C  and  27  °C.  The  characterisation  of  asreceived  and  laser  modified  samples  for  hardness,  microstructure  and  thermal  fatigue  crack conducted before and after 5000 cycles. From the findings,  the  hardness of the laser  modified samples increased 3 times  from 203.3 HV to 744.6 HV.  However, the  SR  has  also increased from 1.3 µm to the range of 8.97-42.31 µm due to the various parameters  of laser surface modification.  The overlap rate has  a  significant effect on hardness. While,  a low SR  can be obtained at  1900 W of peak power and 10% of overlap rate.  However,  the PRF was an insignificant  parameter to affect the hardness and SR. Prediction model  was developed to identify suitable laser parameters setting for the  intended value  of SR and hardness. The hardness and  microstructure  of laser modified samples before and after  thermal  fatigue  (TF)  test  were  investigated.  The  hardness  of  laser  modified  samples  decreased dramatically due to the  microstructure  changed. However, the laser modified  samples significantly performance well than the as-received AISI H13. Laser modified  samples reduce the number and length of cracks from 27 to 17 and 6.87 mm to 1.84 mm respectively. In conclusion, a suitable laser parameters setting can produce a low SR and  high  hardness  sample.  The  thermal  fatigue  test  proved  that  high  hardness  has  a  high resistance of thermal fatigue which can  reduce the thermal fatigue cracks.  Low SR  can  also reduce the accumulation of oxide which can generate the thermal fatigue cracks.  Overall, this study  is  significant to  enhance  the  surface properties such as resistance of  thermal fatigue and hardness for AISI H13 tool steel in high temperature applications.</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Annie Lau Sheng</note>
  <note>Faculty of Manufacturing and Mechatronic Engineering Technology</note>
  <note>Thesis (Master of Science) -- Universiti Malaysia Pahang – 2020</note>
  <note>Includes bibliographical references</note>
  <subject authority="lcsh">
    <name type="corporate">
      <namePart>Faculty of Manufacturing and Mechatronic Engineering Technology</namePart>
    </name>
    <topic>Dissertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Universities and colleges</topic>
    <topic>Dissertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Theses</topic>
  </subject>
  <identifier type="isbn">THE0009130(Local)</identifier>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">220303</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251125105843.0</recordChangeDate>
    <languageOfCataloging>
      <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
    </languageOfCataloging>
  </recordInfo>
</mods>
