<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>04551ntm a2200361 i 4500</leader>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">REF</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="c">REF</subfield>
    <subfield code="d">2022-03-15</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">FTKEE .A96 2021 r Thesis</subfield>
    <subfield code="p">T000001529</subfield>
    <subfield code="r">2022-05-09 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2022-03-15</subfield>
    <subfield code="y">THESIS</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">REF</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="c">REF</subfield>
    <subfield code="d">2022-03-15</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD12934</subfield>
    <subfield code="p">T000001530</subfield>
    <subfield code="r">2022-07-04 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2022-03-15</subfield>
    <subfield code="y">THESIS</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">96388</subfield>
    <subfield code="d">96394</subfield>
  </datafield>
  <controlfield tag="003">MY-KuUP</controlfield>
  <controlfield tag="005">20251125105951.0</controlfield>
  <controlfield tag="006">t||||fr|||| 000 0 </controlfield>
  <controlfield tag="008">220315s2021    my a|||frm||| 00| 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0009162(Local)</subfield>
    <subfield code="q">hardback</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
    <subfield code="b">eng</subfield>
    <subfield code="c">UMP</subfield>
    <subfield code="e">rda</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">FTKEE .A96 2021 r Thesis</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Muhammad Aznil Ab Aziz,</subfield>
    <subfield code="e">author.</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Development of wwm system using mlnn-ga for ph prediction of water quality in catchment area /</subfield>
    <subfield code="c">Muhammad Aznil Ab Aziz</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="1">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2021</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="4">
    <subfield code="c">&#xA9; 2021</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xiv, 114 pages :</subfield>
    <subfield code="b">illustrations (some color) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 CD ROM</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="a">text</subfield>
    <subfield code="2">rdacontent</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="a">text</subfield>
    <subfield code="2">rdacontent</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="a">unmediated</subfield>
    <subfield code="2">rdamedia</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="a">computer</subfield>
    <subfield code="2">rdamedia</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="a">volume</subfield>
    <subfield code="2">rdacarrier</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="a">computer disc</subfield>
    <subfield code="2">rdacarrier</subfield>
  </datafield>
  <datafield tag="347" ind1=" " ind2=" ">
    <subfield code="a">text file</subfield>
    <subfield code="b">PDF</subfield>
    <subfield code="2">rda</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Faculty of Electrical &amp; Electronics Engineering</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Thesis (Master of Science) -- Universiti Malaysia Pahang &#x2013; 2021</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Includes bibliographical references</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Water quality is crucial to maintain as water is  a necessity in our daily life. In aquatic  ecosystem, good water quality allows aquatic life to have good health and improving their  productivity leads to significant benefits to the environment. However, the method of  collecting data is still in manual way. Data samples need to be collected and evaluated in  the laboratory. It leads the results of water quality took a long time to retrieve and cannot  be obtained continuously. Hence, a system is required to monitor the water quality that  capable  to  obtain  the  results  fast  and  continuously.  In  this  research  studies,  Wireless  Passive Water Quality Catchment Monitoring System or WMM System is introduced to  collect the water quality parameters. Five parameters are measured in the system, which  are potential hydrogen (pH), temperature, light intensity of water, coordinate of  collecting  data, and wave velocity. Primary lake at University Malaysia Pahang is selected as the  experimental area for the WWM System. However, coverage area of the lake is large and  require many  WWM Systems to be developed.  This method is expensive in terms of  budget expenditure. Thus, prediction of water quality is applied to solve this problem  with  a  number  of  WWM  Systems  used  for  collecting  data  will  be  reduced.  Artificial  Neural Network or ANN is one of the methods that commonly used to predict the quality  of water. The structure and function of ANN is based on biological neural network. ANN  process consists of three layer which are input layer, hidden layer, and output layer and  weight of the network usually adjusted by using back-propagation (BP) technique. This  technique has several advantages which are fast, simple, and easy to program. However,  there are some weaknesses identified in BP such as being often trapped in local minima,  sensitive to noisy data, and the performance of BP on certain problems is dependent on  the input data. In this research study, Multi-Layer Neural Network optimized by Genetic  Algorithm  (MLNN-GA)  is  introduced  to  predict  the  water  quality.  This  model  will  predict the pH value obtained by WWM System based on the value of pH surrounding  within 100m2 area. MLNN-GA contain three hidden layers and Genetic Algorithm (GA)  will optimize the weight of neural network during the training process. GA has several  advantages,  which are less often trapped in local minima and can operate in a complex  process such as extended neural network. In training process of MLNN-GA, number of  neurons in a hidden layer will be tested to obtain the best accuracy. The parameter of pH  is chosen  for predicting water quality as pH is one important parameter that can influence  the condition of water. MLNN-GA is a new method proposed in this research study for  predicting  the  water  quality  in  terms  of  pH  value.  The  results  of  prediction  will  be  compared with BP technique and the average value of pH within the 100m2 area. The  results  of  prediction  obtained  by  MLNN-GA  model  with  99.64%  accuracy  has  a  significant potential to be used in the future and WWM System has a great potential to  be used in monitoring water quality.</subfield>
  </datafield>
  <datafield tag="610" ind1="2" ind2="0">
    <subfield code="a">Faculty of Electrical &amp; Electronics Engineering Technology</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Universities and colleges</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Theses</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">lcc</subfield>
    <subfield code="c">THESIS</subfield>
  </datafield>
</record>
