    <title>Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control</title>
  </titleInfo>
  <name type="personal">
    <namePart>Wan Nur Huda Aqilah Alias</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
    <role>
      <roleTerm type="text">author.</roleTerm>
    </role>
  </name>
  <typeOfResource manuscript="yes">text</typeOfResource>
  <genre authority="marc">theses</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">my</placeTerm>
    </place>
    <dateIssued encoding="marc">2021</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>xv, 91 pages : illustrations (some color) ; 30 cm. + 1 CD ROM</extent>
  </physicalDescription>
  <abstract>The  advancement  of  technology  and  the  increase  in  population  have  increased  the  demand for electrical supply as well. The drawbacks of electrical generating from nonrenewable energy to the environment have encouraged the researchers to produce clean  and sustained power in vast quantities from sustainable energy.  Recently, PV systems are  frequently  used  owing  to  its  light  and  easy-to-install  characteristics.  Although  it  was  proven auspicious, faults can happen on the grid side of a grid-connected PV system,  causing overshoot DC voltage and overcurrent. Thus, stressing the electrical component,  lessening the system’s power quality and inverter’s trip. Therefore, many FRT strategies  have been introduced to overcome these issues. This thesis proposed a new approach to  alleviate this matter by controlling zero switching state of NPC inverter while injecting  reactive  current  to  the  grid.  First,  the  development  of  a  two-stage  grid-connected  PV  system was stated and the effects of grid faults were deliberated. Some conventional FRT  strategies  employed  in  the  grid-connected  PV  system  were  studied.  Furthermore,  the  efficiency of the scheme was verified by comparing it with a conventional method using  DC chopper. The results showed the proposed method could lessen the overshoot DC  voltage and injecting reactive current to the grid. Also, the results shown were similar to  those of the conventional method.</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Wan Nur Huda Aqilah Alias</note>
  <note>Faculty of Electrical &amp; Electronics Engineering</note>
  <note>Thesis (Master of Science) -- Universiti Malaysia Pahang – 2021</note>
  <note>Includes bibliographical references</note>
  <subject authority="lcsh">
    <name type="corporate">
      <namePart>Faculty of Electrical &amp; Electronics Engineering Technology</namePart>
    </name>
    <topic>Dissertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Universities and colleges</topic>
    <topic>Dissertations</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Theses</topic>
  </subject>
  <identifier type="isbn">THE0009164(Local)</identifier>
  <recordInfo>
    <recordContentSource authority="marcorg">UMP</recordContentSource>
    <recordCreationDate encoding="marc">220315</recordCreationDate>
    <recordChangeDate encoding="iso8601">20251125105952.0</recordChangeDate>
    <languageOfCataloging>
      <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
    </languageOfCataloging>
  </recordInfo>
</mods>