<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>03511ntm a2200349 i 4500</leader>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">REF</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="c">REF</subfield>
    <subfield code="d">2022-04-28</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">KK .P43 2021 r Thesis</subfield>
    <subfield code="p">T000001850</subfield>
    <subfield code="r">2022-06-09 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2022-04-28</subfield>
    <subfield code="y">THESIS</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">REF</subfield>
    <subfield code="a">20000</subfield>
    <subfield code="b">20000</subfield>
    <subfield code="c">REF</subfield>
    <subfield code="d">2022-04-28</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD13091</subfield>
    <subfield code="p">T000001851</subfield>
    <subfield code="r">2022-04-28 00:00:00</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2022-04-28</subfield>
    <subfield code="y">THESIS</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">97105</subfield>
    <subfield code="d">97111</subfield>
  </datafield>
  <controlfield tag="003">MY-KuUP</controlfield>
  <controlfield tag="005">20251125110041.0</controlfield>
  <controlfield tag="006">t||||fr|||| 000 0 </controlfield>
  <controlfield tag="008">220428s2021    my a|||frm||| 000 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">THE0009352(Local)</subfield>
    <subfield code="q">hardback</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">UMP</subfield>
    <subfield code="b">eng</subfield>
    <subfield code="c">UMP</subfield>
    <subfield code="e">rda</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">KK .P43 2021 r Thesis</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Peddakapu Kurukuri,</subfield>
    <subfield code="e">author.</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Frequency deviations stabilizations in restructured power systems using coordinative controllers /</subfield>
    <subfield code="c">Peddakapu Kurukuri</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="1">
    <subfield code="a">Kuantan, Pahang :</subfield>
    <subfield code="b">UMP,</subfield>
    <subfield code="c">2021</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2="4">
    <subfield code="c">&#xA9; 2021</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xvi, 189 pages :</subfield>
    <subfield code="b">illustrations (some color) ;</subfield>
    <subfield code="c">30 cm. +</subfield>
    <subfield code="e">1 CD ROM</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="a">text</subfield>
    <subfield code="2">rdacontent</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="a">text</subfield>
    <subfield code="2">rdacontent</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="a">unmediated</subfield>
    <subfield code="2">rdamedia</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="a">computer</subfield>
    <subfield code="2">rdamedia</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="a">volume</subfield>
    <subfield code="2">rdacarrier</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="a">computer disc</subfield>
    <subfield code="2">rdacarrier</subfield>
  </datafield>
  <datafield tag="347" ind1=" " ind2=" ">
    <subfield code="a">text file</subfield>
    <subfield code="b">PDF</subfield>
    <subfield code="2">rda</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">College of Engineering</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Thesis (Doctor of Philosophy) -- Universiti Malaysia Pahang &#x2013; 2021</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Modern  restructured  power  system  faces  excessive  frequency  aberrations  due  to  the  intermittent renewable generations and persistently changing load demands. An efficient  and robust control strategy is obligatory to minimise deviations in the system frequency  and tie-line to avoid any possible blackout. Hence, in this research, to achieve this target,  automatic generation control (AGC) is utilized as a secondary controller to alleviate the  changes in interconnected restructured systems at uncertainties. The objective of AGC is to  quickly  stabilize  the  deviations  in  frequency  and  tie-line  power  following  load  fluctuations.  This  thesis  addresses  the  performance  of  AGC  in  two-area  restructured  power systems with many sophisticated control strategies in the presence of renewable  and traditional power plants. As per literature of research work,  there are  quite a few  research  studies  on  AGC  of  a  restructured  system  using  optimized  coordinative  controllers. Besides, investigations on advanced optimized-based coordinative controller  approaches are also rare to find in the literature. So, various combinations of two degrees  of freedom (2DOF) controllers are utilized as supplementary controllers to diminish the  frequency deviations. Nevertheless, the interconnected tie-lines are typically  congested  in  areas  with  huge  penetration  of  renewable  sources,  which  may  reduce  the  tie -line  capability. Therefore, distinct FACTS controllers and ultra-capacitor (UC) are integrated  into two-area restructured systems for strengthening the tie-line power and frequency.  Further, new optimization techniques such as cuckoo search (CS), bat algorithm (BA),  moth-flame optimization (MFO) are utilized in this work for investigating the suggested  2DOF  controllers  and  compared  their  performance  in  all  contracts  of  restructured  systems. As per the simulation outcomes, the amalgamation of DPFC and UC with MFObased 2DOF PID-FOPDN shows low fluctuation rate in frequency and tie-line power.  Besides, the settling times (ST) of two areas are 9.5 S for &#x394;F1, 8.2 S for &#x394;F2, and 10.15  S  for  &#x394;Ptie.  The  robustness  of  the  suggested  controller  has  been  verified  by  &#xB1;25%  variations in system parameters and loading conditions.</subfield>
  </datafield>
  <datafield tag="610" ind1="2" ind2="0">
    <subfield code="a">College of Engineering</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Universities and colleges</subfield>
    <subfield code="x">Dissertations</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Theses</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">lcc</subfield>
    <subfield code="c">THESIS</subfield>
  </datafield>
</record>
