Extraction and separation of hylocereus polyrhizus waste extract using membrane reactor: effect of transmembrane pressure and cross flow velocity / Azimah Saman

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2010Description: xv, 74 p. : ill. (some col.) ; 30 cm. + 1 computer discISBN:
  • THE0003978(Local)
Subject(s): Dissertation note: Project paper (Bachelor of Chemical Engineering (Biotechnology)) -- Universiti Malaysia Pahang - 2010 Abstract: This research study about the influence of cross-flow velocity (CFV) and transmembrane pressure (TMP) on the flux decline during separation of hylocereus pholyrizhus waste extract. Hylocereus pholyrizhus waste extract was selected because of red hylocereus pholyrizhus easily find in local market and its can reduce waste production in the world, which is environmental friendly. The research was conducted by using membrane reactor provided at Universiti Malaysia Pahang. The hylocereus pholyrizhus waste extract was extracted at 6 hours and after that it was filtrate using ceramic membrane filtration. The filtration was filtrate at temperature 400. During filtration, each 5 minutes the volume of hylocereus pholyrizhus waste extract filtrate was collected. The volume was collected until the volume of filtrate was constant. The flux decline of filtration for CFV and TMP was calculated. This research applied response. Surface methodology (RSM) to optimization he experiment condition. The experiment plan was based on the central composite design (CCD) For the CFV the range of flux decline at time 10 to 25 minutes. For the TMP the range of flux decline at the time 10 to 20 minutes. The highest CFV and TMP can cause the membrane easy to foul. For CFV, the best result is 0.06m/s while for TMP is 0.5 bars.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TP156.E8 A95 2010 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000060264
Final Year Report Final Year Report UMPLIB GAMBANG CD 5519 | TP156.E8 A95 2010 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000060265

Project paper (Bachelor of Chemical Engineering (Biotechnology)) -- Universiti Malaysia Pahang - 2010

Bibliography : p. [73] - 74

This research study about the influence of cross-flow velocity (CFV) and transmembrane pressure (TMP) on the flux decline during separation of hylocereus pholyrizhus waste extract. Hylocereus pholyrizhus waste extract was selected because of red hylocereus pholyrizhus easily find in local market and its can reduce waste production in the world, which is environmental friendly. The research was conducted by using membrane reactor provided at Universiti Malaysia Pahang. The hylocereus pholyrizhus waste extract was extracted at 6 hours and after that it was filtrate using ceramic membrane filtration. The filtration was filtrate at temperature 400. During filtration, each 5 minutes the volume of hylocereus pholyrizhus waste extract filtrate was collected. The volume was collected until the volume of filtrate was constant. The flux decline of filtration for CFV and TMP was calculated. This research applied response. Surface methodology (RSM) to optimization he experiment condition. The experiment plan was based on the central composite design (CCD) For the CFV the range of flux decline at time 10 to 25 minutes. For the TMP the range of flux decline at the time 10 to 20 minutes. The highest CFV and TMP can cause the membrane easy to foul. For CFV, the best result is 0.06m/s while for TMP is 0.5 bars.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us