A study on the performance of local exhaust ventilation system using Mahalanobis approach / Muhammad Hasbi Abd Halid

By: Material type: TextTextPublication details: Kuantan, Pahang : UMP, 2013Description: xiii, 68 p. : ill. ; 30 cm. + 1 CD-ROMISBN:
  • THE0003312(Local)
Subject(s): Dissertation note: Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2013 Abstract: The title of this experiment is a study on the performance of local exhaust ventilation system using Mahalanobis approach. The objectives of this study are to obtain normal pattern operation of local exhaust ventilation (LEV) system and to characterize the pattern to study the performance of the above system. An experiment was conducted in determining the average face velocity of the fume hood. This was done by taking several readings at equidistant points. The average face velocity was checked on reference guidelines of fume hood to see whether the fume hood is safe to use or otherwise. Then, with the same data obtained from the experiment, it was analysed using Mahalanobis Distance approach. Then, the result of both methods will be compared. After it had been analysed, 5 points of face velocity were obtained compared to the 16 initial points, thus proving Mahalanobis approach making it a better and faster way in determining the performance of the fume hood and the LEV system.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Call number Copy number Status Date due Barcode
Final Year Report Final Year Report UMPLIB GAMBANG TD884.5 .H37 2013 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000074599
Final Year Report Final Year Report UMPLIB GAMBANG CD 6999 | TD884.5 .H37 2013 rs Bc. (Browse shelf(Opens below)) 1 Not for loan 0000074600

Project paper (Bachelor of Chemical Engineering) -- Universiti Malaysia Pahang – 2013

Bibliography : p. 59-60

The title of this experiment is a study on the performance of local exhaust ventilation system using Mahalanobis approach. The objectives of this study are to obtain normal pattern operation of local exhaust ventilation (LEV) system and to characterize the pattern to study the performance of the above system. An experiment was conducted in determining the average face velocity of the fume hood. This was done by taking several readings at equidistant points. The average face velocity was checked on reference guidelines of fume hood to see whether the fume hood is safe to use or otherwise. Then, with the same data obtained from the experiment, it was analysed using Mahalanobis Distance approach. Then, the result of both methods will be compared. After it had been analysed, 5 points of face velocity were obtained compared to the 16 initial points, thus proving Mahalanobis approach making it a better and faster way in determining the performance of the fume hood and the LEV system.

Perpustakaan Universiti Malaysia Pahang Al-Sultan Abdullah
26600 Pekan, Pahang Darul Makmur
Phone: +609 431 5063 (Gambang) / +609 431 5035 (Pekan)
Email: umplibrary@umpsa.edu.my

Connect With Us