000 03954ntm a2200337 i 4500
999 _c100813
_d100819
003 MY-KuUP
005 20251125110857.0
006 t||||fr|||| 000 0
007 ta
008 240527t20232023my a|||fr|||| 000 0 eng d
020 _aTHE0009849 (Local)
_qHardback
040 _aUMPSA
_beng
_cUMP
_erda
090 _aFTKA .A36 2023 r Thesis
100 1 _aMuhammad Aimran Amzar Bin Kamarudin,
_eauthor.
245 1 0 _aThe assessment of tall building structure performance due to seismic effect in malaysia /
_cMuhammad Aimran Amzar Bin Kamarudin
264 1 _aKuantan, Pahang :
_bUMPSA,
_c2023
264 4 _c©2023
300 _axiv,126 pages :
_billustrations (some color) ;
_c30 cm. +
_e1 CD ROM
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
338 _2rdacarrier
_avolume
347 _2rda
_atext file
_bPDF
500 _aFaculty of Civil Engineering Technology
502 _aThesis (Master of Science) -- Universiti Malaysia Pahang – 2023
504 _aIncludes bibliographical references
520 3 _aRecent natural disasters have brought attention to the vulnerability of buildings in Malaysia, resulting in severe damage, loss of life, and economic setbacks. Many existing reinforced concrete structures in the country were not adequately designed to withstand seismic forces, as they primarily focused on vertical loads. Therefore, it is crucial to evaluate the seismic performance of buildings to ensure their safety during earthquakes. This research aims to develop fragility curves specific to tall concrete buildings in Malaysia. The study analyzes two building models, differing in the number of stories: a 30-story building and a 25-story building. The analysis involves pushover analysis and incremental dynamic analysis, considering gravity and wind loads as per the Malaysian standard practice (Eurocode 2). Lateral design loads are utilized for the pushover analysis, while five records of far-field ground motion are employed for the incremental dynamic analysis. Furthermore, different soil types are taken into consideration to assess their impact on the structural response. Capacity curves based on lateral load are developed, incorporating the influence of building geometry. Fragility curves are produced through the examination of inter-story drift ratios recorded during the evaluation of five distinct ground motions for each soil classification, along with incremental variations in peak ground acceleration. The structural performance is evaluated using five distinct performance levels: operational phase (OP), immediate occupancy (IO), damage control (DC), life safety (LS), and collapse prevention (CP). Fragility curves are developed for both building models, considering the four soil types. The findings reveal that the inter-story drift ratio or damage measure values increase with higher peak ground accelerations. Additionally, the pushover analysis indicates that the 30-story model exhibits higher base shear compared to the 25-story model suggesting a correlation between base shear and building height. A total of eight fragility curves are constructed, representing the probability of exceeding IO and CP limit states. Notably, under soil type A bedrock with a peak ground acceleration of 0.1 g, the 30-story building demonstrates better performance compared to the 25-story building, with maximum probabilities of exceeding CP damage states of 4% and 8% respectively. The fragility curves highlight the significant influence of soil conditions on structural vulnerability. These findings contribute valuable insights that can inform future construction practices, enhance building codes, and guide seismic mitigation strategies, particularly in regions with similar geological conditions.
610 2 0 _aFaculty of Civil Engineering Technology
_xDissertations
650 0 _aUniversities and colleges
_xDissertations
650 0 _aTheses
_xDissertations
942 _2lcc
_cTHESIS