000 03698ntm a2200337 i 4500
999 _c101167
_d101173
003 MY-KuUP
005 20251125110919.0
006 t||||fr|||| 000 0
007 ta
008 240822t20242024my a|||fr|||| 000 0 eng d
020 _aTHE0009923 (Local)
_qHardback
040 _aUMPSA
_beng
_cUMP
_erda
090 _aFTKMA .F34 2024 r Thesis
100 0 _aAhmad Fahmi Huwaidi Bin Mohamad Noor,
_eauthor.
245 1 0 _aPiv-based investigation of haemodynamic factors in diseased carotid artery bifurcation /
_cAhmad Fahmi Huwaidi Bin Mohamad Noor
264 1 _aKuantan, Pahang :
_bUMPSA,
_c2024
264 4 _c© 2024
300 _axiii, 111 pages :
_billustrations (some color) ;
_c30 cm. +
_e1 CD ROM
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
338 _2rdacarrier
_avolume
347 _2rda
_atext file
_bPDF
500 _aFaculty of Mechanical and Automotive Engineering Technology
502 _aThesis (Master of Science) -- Universiti Malaysia Pahang – 2024
504 _aIncludes bibliographical references
520 3 _aIschemic stroke, often precipitated by the development of plaque within the carotid arteries leading to carotid artery stenosis, represents a significant health concern. This condition is heavily influenced by hemodynamic parameters such as velocity profiles, wall shear stress, and pressure within the blood flow. Addressing this, the current study endeavors to elucidate the flow characteristics at carotid artery bifurcations by employing particle image velocimetry (PIV) and computational models, and to ascertain the impact of stenosis placement on these hemodynamic parameters. The initial phase of this research involves the examination of flow patterns in a post-stent carotid artery bifurcation phantom using both 2D PIV and 3D stereo-PIV (SPIV). These findings are subsequently juxtaposed with those derived from computational fluid dynamics (CFD) analyses, concentrating on areas of interest that include the inlet, bifurcation, and stented segments. Additionally, this study constructs and examines idealized models of varying stenosis locations, evaluating them based on the velocity profiles, wall shear stress, and pressure at the sites of stenosis. Results reveal a reduced flow velocity in the bifurcation area, with consistent trends between PIV and SPIV methodologies. A notable yet acceptable variance of about 16.66% in average flow velocity was discerned between the 2D and 3D PIV approaches. Despite SPIV's enhanced precision in vector capture, this minor disparity validates the use of PIV for comprehensive CFD comparison within the purview of this research. Comparative analysis of velocity vectors in the post-stent area demonstrates analogous trends between PIV and CFD, while the inlet region displays more significant differences, notably the higher velocities detected by CFD. Here, CFD anticipates a maximum velocity of 0.98 m/s, approximately 10% higher than that measured by PIV. The observed low-velocity zones around bifurcations and curvatures are conducive to recirculatory flow, fostering atherosclerotic progression. Moreover, the research identifies that Type I stenosis upstream stenosis is more prone to result in intraplaque hemorrhage (IPH), potentially exacerbating patient outcomes. The insights from this study enhance our comprehension of vascular mechanics and hold the potential to refine clinical approaches to managing carotid artery disease.
610 2 0 _aFaculty of Mechanical and Automotive Engineering Technology
_xDissertations
650 0 _aUniversities and colleges
_xDissertations
650 0 _aTheses
_xDissertations
942 _2lcc
_cTHESIS