000 03215nam a2200337 i 4500
999 _c102545
_d102551
003 MY-KuUP
005 20251125111041.0
006 t||||fr|||| 000 0
007 ta
008 250516s20252025my a|||fr|||| 000 0 eng d
020 _aTHE0010079 (Local)
_qHardback
040 _aUMPSA
_beng
_cUMPSA
_erda
090 _aFTKPM .S93 2025 r Thesis
100 0 _aMuhammad Syawal Mat Jahak,
_eauthor.
245 1 0 _aEstimation of speed-sensitive thermal model for dc machines using transfer function /
_cMuhammad Syawal Bin Mat Jahak
264 1 _aKuantan, Pahang :
_bUMPSA,
_c2025
264 4 _c© 2025
300 _axvii, 168 pages :
_billustrations ;
_c30 cm. +
_e1 CD-COM
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
338 _2rdacarrier
_avolume
347 _2rda
_atext file
_bPDF
500 _aFaculty of Manufacturing and Mechatronic Engineering Technology
502 _aThesis (Master of Science) -- Universiti Malaysia Pahang – 2025
504 _aIncludes bibliographical references
520 3 _aMotors account for 40% of global electricity consumption and 13% of carbon emissions and often suffer irreversible thermal damage. To prevent excessive electrical waste and improve reliability, it’s crucial to monitor motor temperature accurately and halt operation at safe levels. This study aims to develop a real-time model for monitoring motor temperature in MY1016 direct current machines, using a transfer function. The objectives include identifying the most precise transfer function to model the temperature response of each component at different speed, developing, and validating a generalized model using averaged-pole and variable-pole transfer function models, and finally evaluating their feasibility for fault detection. Experimental data was recorded for different motor components including the brush, bearing, permanent magnet and casing. The motor was operated at speeds from 20% to 100% of nominal speed with no load, until thermal equilibrium was reached. The MATLAB system identification toolbox was used to identify the transfer function, with a number of poles varying from 1 to 4 and with no zeros. The study found that the temperature response of the MY1016 motor at 60% of the nominal speed produces the highest temperature. The brush was best represented by a 3rd order transfer function, while a 1st order transfer function is sufficient to represent other components. The non-LTI characteristic of the temperature response observed from the pole analysis led to a choice of modeling using variable-pole transfer function to create the baseline temperature model. It can estimate temperature response during both steady and transient speed states, with a maximum temperature difference of 10 ℃. The study concludes that the variable-pole transfer function can be used to monitor electric motors' condition using several testing scenarios. The same method can be suggested to be applied on other types of motors.
610 2 0 _aFaculty of Manufacturing and Mechatronic Engineering Technology
_xDissertations
650 0 _aUniversities and colleges
_xDissertations
650 0 _aTheses
_xDissertations
942 _2lcc
_cTHESIS