000 02871ntm a2200349 i 4500
003 MY-KuUP
005 20260414172315.0
006 t||||fr|||| 000 0
007 ta
008 260115t20252025my a|||fr|||| 000 0 eng d
020 _aTHE0010278 (Local)
_qHardback
040 _aUMPSA
_beng
_cUMPSA
_erda
090 _aFIST .A45 2025 r Bc.
100 0 _aMuhammad Amiruddin Bin Shuhairi,
_eauthor.
245 1 0 _aInhalation risk of teachers to airborne microplastics exposure in indoor daycare centre /
_cMuhammad Amiruddin Bin Shuhairi
264 _aKuantan, Pahang :
_bUMPSA,
_c2025
264 _c© 2025
300 _axii, 87 pages :
_billustrations ;
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
338 _2rdacarrier
_avolume
347 _2rda
_atext file
_bPDF
500 _aFaculty of Industrial Sciences and Technology
502 _aFinal Year Report (Bachelor of Occupational Safety and Health ) -- Universiti Malaysia Pahang Al-Sultan Abdullah - 2025
504 _aInclude bibliographical reference
520 3 _aThe study addressed the problem of exposure to airborne microplastics (AMPs) in daycare centers, highlighting the potential health risks for teachers due to insufficient data on their presence. The research aimed to determine the concentration of MPs in indoor air, identify their I/O ratios, and explore the correlation between various factors influencing MP concentrations. Nine samples were collected from three daycare centres which located in Kuantan District, Pahang, the concentration of indoor AMP is markedly higher than the outdoor AMP where Daycare Centre B accounted for 89.79 MP/m3 (74.69- 109.17) MP/m3 indoor and 86.88 MP/m3 (69.38-90.10) MP/m3 outdoor and Daycare Centre C with median (IQR) indoor and outdoor AMP concentration was 161.88 (123.44-170.63) MP/m3 and 112.71 (81.56-121.25) MP/m3. The analysis revealed an average indoor-to-outdoor ratio of 1, indicating higher levels of MPs indoors than outdoor environments. Additionally, no significant correlations (p > 0.05) were found between indoor MP concentrations and driving factors (indoor air velocity, indoor temperature, indoor relative humidity, number of occupants, type of building, type of ventilation EDI ranges from 136.54 to 278.69 MP/kg-day. There is an inverse relationship between teacher bodyweight and EDI. The study concluded that daycare centers are critical environments for monitoring AMP exposure, emphasizing the need for improved air quality standards to protect teachers from developing chronic respiratory problems from prolonged exposure
610 2 0 _aFaculty of Industrial Sciences and Technology
_xDissertations
650 0 _aUniversities and colleges
_xDissertations
650 0 _aFinal Year Report
_xDissertations
856 _uhttp://umpir.ump.edu.my/id/eprint/45535
942 _2lcc
_cPSM
999 _c103885
_d103891