000 03382ntm a2200337 i 4500
003 MY-KuUP
005 20260624175620.0
006 t|||||r|||| 000 0
007 ta
008 260624t20242024my a|||fr|||| 000 0 eng d
020 _aTHE0010636 (Local)
_qHardback
040 _aUMPSA
_beng
_cUMPSA
_erda
090 _aFTKKP .S536 2024 r Bc.
100 1 _aOng, Shao Jie,
_eauthor.
245 1 0 _aPerformance of attached growth microbial fuel cell (ag-mfc) in treating palm oil wastewater /
_b
_cOng Shao Jie
264 1 _aKuantan, Pahang :
_bUMPSA,
_c2024
264 4 _c© 2024
300 _axviii, 43 pages :
_billustrations ;
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
338 _2rdacarrier
_avolume
347 _2rda
_atext file
_bPDF
500 _aFaculty of Chemical and Process Engineering Technology
502 _aFinal Year Report (Bachelor of Chemical Engineering ) -- Universiti Malaysia Pahang Al-Sultan Abdullah - 2024
504 _aInclude bibliographical reference
520 3 _aThe research focuses on the use of Attached Growth Microbial Fuel Cell (AG-MFC) for palm oil wastewater (POME) treatment, aiming to improve pollutant removal efficiency while generating electricity. AG-MFC convert organic matter into electricity, while Granular Activated Carbon (GAC) enhances pollutant removal by supporting microbial attachment and adsorption. The research aims to study the optimum GAC dosage for removing COD, BOD, O&G, and turbidity from POME, as well as identifying the bacteria morphology attached to GAC in AG-MFC. The study scope encompasses sample collection, acclimatization, shaker tests, AG-MFC setup, a 30-day treatment phase, FESEM and EDX analyses. Performance evaluation across various Organic Loading Rates (OLR) considers COD, BOD, Colour, O&G, and turbidity removal efficiency, along with energy recovery efficiency. A GAC dosage of 20 g/L, chosen through shaker tests, is implemented in a 30-day treatment cycle. The study on 30-day treatment with three different COD influent concentrations, 1500 mg/L, 2000 mg/L, and 3000 mg/L, showed that an increase in COD influent could increase removal efficiency for COD, BOD, O&G, and turbidity, except for colour. An elevated COD influent concentration could enhance electricity generation. The influent with a 3000 mg/L COD concentration consistently demonstrated superior performance, achieving removal efficiencies of 96.49%, 98.41%, 19.39%, 92.84%, and 98.53% for COD, BOD, Colour, O&G, and turbidity, and an average electricity generation of 250.66 mV. The 3000 mg/L COD influent remains a feasible choice, provided that supplementary colour removal methods are integrated into the system. The FESEM analysis revealed the potential presence of thermophilic bacteria including Bacillus coagulans, Bacillus smithii, and Thermoanaerobacterium thermosaccharolyticum in AG-MFC. The EDX analysis on GAC demonstrated significant capabilities in adsorbing organic matter and metal contaminants in POME. AG-MFC provides efficient POME treatment, but careful consideration is needed for efficient parameter removal, particularly colour, to comply with standard discharge limits.
610 2 0 _aFaculty of Chemical and Process Engineering Technology
_xDissertations
650 0 _aUniversities and colleges
_xDissertations
650 0 _aTheses
_xDissertations
942 _2lcc
_cPSM
999 _c105037
_d105043