000 02693nam a2200241 a 4500
001 vtls000029445
003 KUKTEM
005 20251114204412.0
008 080612t2007 my f m 000 0 eng|d
020 _aTHE0003102(Local)
039 9 _a201905161210
_bzul
_c201107132225
_dVLOAD
_c200908141505
_dVLOAD
_c200908141435
_dVLOAD
_y200806121404
_zkam
040 _aUMP
090 _aTD403 .M43 2007 rs Thesis
100 0 _aMuhammad Fadli Pharo
245 1 2 _aA study on the quantity and quality of groundwater supply at Nenasi water treatment plant /
_cMuhammad Fadli bin Pharo
260 _aKuantan :
_bUMP,
_c2007
300 _a55 p. :
_bill. ;
_c31 cm.
502 _aProject paper (Bachelor of Civil Engineering) -- Universiti Malaysia Pahang - 2007
520 3 _aGroundwater is one of the most suitable alternative of water supply which we can rely on in this era because of its large quantity that is nearly 30% of the total global freshwater. In this thesis, a case study is conducted in one of the area which uses groundwater as its main daily supply that is Bebar sub-district in Pekan, Pahang. The case study is mainly focus on the quantity of supply by the treatment plant whether it is design to meet the demand from the increasing population of Bebar sub¬district. The methodology used in fmding the capability of the Treatment plant to supply water is by doing data collection on the population in Bebar sub-district, and the water demand until 20 years for the residents and comparing it to the Water Treatment plant design capacity. The water demand is calculated by a standard formula by Malaysian Water Association (MW A) for water demand. In situ tests and lab experiments are also conducted to find out the quality of the groundwater extracted whether it comply with the WHO Drinking Water Standards 1993 Guidelines Level. The parameters which are being focus on are Iron (Fe), salinity, Total Dissolved Solids (TDS), pH, and Conductivity. From the conducted quantity analysis, it can be concluded that the recent design capacity of the water treatment plant is able to meet the water demand of Bebar Sub-district residents for 20 years. Meanwhile, for the quality analysis conducted, among the 5 parameters checked, only the Iron parameters is showing an undesirable results where the content is higher than the acquired standard (0.3 mg/l). Nevertheless, the quality of the groundwater at Nenasi is still considered safe to be used as drinking water since there is no health effects occurred so far. -Author
650 0 _aGroundwater
_xResearch
650 0 _aGroundwater
_xQuality
999 _aVIRTUA40
_c1422
_d1428
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5020*5200*6500*6501*9992