| 000 | 02581nam a2200253 a 4500 | ||
|---|---|---|---|
| 001 | vtls000025784 | ||
| 003 | KUKTEM | ||
| 005 | 20251114204417.0 | ||
| 008 | 080326t2007 my f m 000 0 eng|d | ||
| 020 | _aTHE0006696(Local) | ||
| 039 | 9 |
_a201905171514 _bamirul _c201107132238 _dVLOAD _c200908141421 _dVLOAD _c200908141353 _dVLOAD _y200803261700 _zkam |
|
| 040 | _aUMP | ||
| 090 | _aTK1025 .A97 2007 rs Thesis | ||
| 100 | 0 | _aMohd Azraie Suarin | |
| 245 | 1 | 0 |
_aAutomatic tester device for earth leakage circuit breaker (ELCB) / _cMohd Azraie B Suarin |
| 246 | 3 |
_aAutomatic tester device for earth leakage circuit breaker (ELCB) _h[electronic resource] |
|
| 260 |
_aKuantan, Pahang : _bUMP, _c2007 |
||
| 300 |
_a82 p. : _bill. (some col.) ; _c30 cm. + _e1 computer disc |
||
| 502 | _aProject paper (Bachelor of Electrical Engineering (Power systems)) -- Universiti Malaysia Pahang - 2007 | ||
| 520 | 1 | _aPower system protection plays important role for the safety of humans and electrical equipments in houses or buildings. Besides it also becomes a precondition of the system for obtaining capability and continuous power supply. Earth leakage circuit breaker (ELCB) is an important protection device especially for houses and buildings. The ELCB’s spring trap will trip to isolate the fault from the system when line to ground fault occurs. So the good condition of the ELCB is very important to run the duty as a power system protector. This project is designed to test the earth leakage circuit breaker (ELCB) automatically every month by detecting current through it when it is in off condition. Microcontroller will be use in this project to make the ELCB automatically tested with programmed it for month. During test period, a current detector which is connected series with the ELCB will detect any current that flow through it. When the detector detect currents, mean that the ELCB does not function properly and LED or buzzer will be ON as an indicator for occupant, so that ELCB can be change immediately. The ELCB is in good condition and can function properly when no current detected and DC motor will be used to switch ON the ELCB’s spring trap. Actually this project can improve the ELCB application and also will enhance the safety for occupant of houses and buildings. -Author | |
| 650 | 0 |
_aElectric resistance _xSecurity measures |
|
| 650 | 0 | _aEarth resistance | |
| 999 |
_aVIRTUA40 _c1558 _d1564 |
||
| 999 | _aVTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5200*6500*6501*9992 | ||