000 02927nam a2200265 a 4500
001 vtls000045088
003 KUKTEM
005 20251114204421.0
008 100205t2009 my a f m 000 0 eng‰d
020 _aTHE0003776(Local)
039 9 _a201905131520
_bshah
_c201107132306
_dVLOAD
_c201002091023
_dida
_c201002051001
_dida
_y201002050958
_zida
040 _aUMP
090 _aTP155.75 .A45 2009 rs Bc.
100 0 _aMohamed Afizal Mohamed Amin
245 1 0 _aProcess monitoring on AFPT pilot plant by using statistical process control /
_cMohamed Afizal Mohamed Amin
246 3 _aProcess monitoring on AFPT pilot plant by using statistical process control
_h[electronic resource]
260 _aKuantan, Pahang :
_bUMP,
_c2009
300 _a51 p. :
_bill. (some col.) ;
_c30 cm. +
_e1 computer disc
502 _aProject paper (Bachelor of of Chemical engineering) -- Universiti Malaysia Pahang - 2009
504 _aBibliography : p. 38-39
520 3 _aStatistical Process Control (SPC) technique has been widely develops for fault detection, diagnosis and control tool. Today, the industries have to keep sustainable production and operate as fault free as possible because faults that present in a process operation increase the operating cost due to products with undesired specifications, malfunction of plant equipment and instrumentation. Therefore, this study is conducted to introduce Statistical Process Control method for detecting fault early enough, so that the corrective action can be taken before the process is upset or out of control. For this research, the historical data at normal operating condition is collected by using Air Flow Pressure Temperature (AFPT) Pilot Plant. The generate data then will be ensure distribute normally before further analysis is carried out. Shewhart individual chart and Shewhart range chart are use to facilitate the fault detected. Based on the result, the Shewhart individual capabilities is more precise estimate of the process standard deviation compare to Shewhart range because it has a smaller uncertainty. Besides that, the computation of Shewhart individual involves all the measurements in each sample, while the computation of Shewhart range involves only two measurements (the largest and the smallest). Based on the result obtained, it shows that both Shewhart range and Shewhart individual chart, can detect fault for both process variables (Temperature and Pressure) and quality variables (Density). After the correlation coefficient is determined it show that the gap between UCL and LCL with CL become wider and make the usage of this technique in Shewhart chart for fault detection gives the best for it has the highest fault detection efficiency.-Author-
650 0 _aChemical proses control
_xStatistical methods
650 0 _aOperation research
999 _aVIRTUA40
_c1691
_d1697
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5040*5200*6500*6501*9992