000 02816nam a2200253 a 4500
001 vtls000046000
003 KUKTEM
005 20251114204429.0
008 100607t2009 my dao f m 000 0 eng d
020 _aTHE0006021(Local)
039 9 _a201905151137
_baida
_c201107132323
_dVLOAD
_y201006071011
_zFida
040 _aUMP
090 _aTH7687 .N33 2009 rs Bc.
100 0 _aMohamad Nadzif Zahirudin
245 1 0 _aPerformance evaluation of Proton Waja car air conditioning system /
_cMohamad Nadzif Bin Zahirudin
246 3 _aPerformance evaluation of Proton Waja car air conditioning system
_h[electronic resource]
260 _aKuantan, Pahang :
_bUMP ,
_c2009
300 _axv, 74 p. :
_bill. (some col.) ;
_c30 cm. +
_e1 computer disc
502 _aProject paper (Bachelor of Mechanical Engineering with Automotive Engineering) -- Universiti Malaysia Pahang - 2009
504 _aBibliography : p. 62-63
520 3 _aAir conditioning is a process by which air is cooled or heated, cleaned or filtered, and circulated or recirculated. Air conditioning had become a standard option on most vehicle for enhancing comfort and safety. Regarding to this situation, an experiment and analysis need to be done to analyze the coefficient of performance (COP) of Proton Waja car during variable compressor speed and variable refrigerant weight. There are four locations of temperature measurement were selected in order to analyze the system. These locations are at the inlet and outlet of the compressor, the outlet of the condenser, and the inlet of the evaporator, respectively. The pressure was measured at the low pressure side and high pressure side which are at the outlet of the evaporator and inlet of the condenser, respectively. Before experimenting, a Statistica Software was used to reduce the error of experiment, and this software can design the experiment order. Besides that, the result from manual calculation can be validate with the result from Statistica Software. All of the parameters are measured during the cycle and were analyzed by using the properties table for refrigerant-134a and the p-h diagram for refrigerant-134a in order to determine the heat rejection, cooling effect, work of compressor and the coefficient of performance (COP) of the air conditioning system. The heat rejection, cooling effect, work of compressor, and the COP of the air conditioning system were investigated at variable speed of compressor and variable weight of refrigerant. The COP of the system was decreasing as the increasing of time and the compressor speed. It is also similar to COP of the system during the increasing of refrigerant weight and time in other experiment.
650 0 _aAir conditioning
999 _aVIRTUA40
_c1895
_d1901
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5040*5200*6500*9992