000 02962nam a2200241 a 4500
001 vtls000051589
003 KUKTEM
005 20251114204438.0
008 110302t2010 my da f m 000 0 eng d
020 _aTHE0006027(Local)
039 9 _a201905151149
_baida
_c201107140035
_dVLOAD
_y201103021039
_zFida
040 _aUMP
090 _aTH7687.9 .M34 2010 rs Bc.
100 0 _aMahendran Moorthy
245 1 0 _aPerformance of solar air-conditioning system using heat pipe evacuated tube collector /
_cMahendran Moorthy
246 3 _aPerformance of solar air-conditioning system using heat pipe evacuated tube collector
_h[electronic resource]
260 _aKuantan, Pahang :
_bUMP,
_c2010
300 _axvi, 109 p. :
_bill. (some col.) ;
_c30 cm. + 1 computer disc
502 _aProject paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang -- 2010
520 3 _aThis is a study on the performance of solar air-conditioning system using heat pipe evacuated tube collector. The objective of this project is to analysis the performance solar air-conditioning system by determining the solar collector efficiency, coefficient of performance (COP) of the absorption chiller, and overall system efficiency and also the electrical energy consumption and operation cost for the system and compare it with the conventional air-conditioning system from the previous case study. The existing solar air-conditioning system is not competitive with electricity driven air-conditioning system because of their high investment and installation cost. Its overall thermal energy conversion efficiency is relatively low, and from an economical point of view, solar cooling and refrigeration are not competitive with the conventional systems. The experiment is conducted at Solar District Cooling Sdn. Bhd and data collected from building automation system for 30 days from 1st-30th June 2010. The data analysed using the theoretical analysis and plotted in graph to discuss about it. The solar collector efficiency varies from 50 to 80% during day time and stored energy can be used during night time. The COP varies from 2.961-2.966 and the overall system efficiency is from 30 to 50%. The investment cost is higher and electrical consumption is relatively lower than conventional air-conditioning system. The economical view is profitable after 18 years and 7 months of installation and environmental view is green energy without pollution. Although all the above findings refer to a particular application in Malaysia, the similar results can be obtained in the country with high solar availability. Finally by considering the problem of pollution of the planet due to the burning of fossil fuels the adoption of solar energy to power absorption chillers, even with marginal economic benefits, should not be underestimated.
650 0 _aSolar air conditioning
999 _aVIRTUA40
_c2168
_d2174
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5200*6500*9992