000 03121ntm a2200289 a 4500
001 vtls000092256
003 KUKTEM
005 20251114204450.0
008 151125t2015 my da f abm 000 0 eng d
020 _aTHE0000310(Local)
039 9 _a201905141654
_bnazirah
_c201711291028
_dsaini
_c201511251303
_dasma
_y201511251302
_zasma
040 _aUMP
090 _aFKASA .A86 2015 r Bc.
100 0 _aNor Asmaq Baharom
245 1 4 _aThe effect of screw spacing on the Profiled Steel Sheet Dry Board (PSSDB) with foamed concrete infill floor panel stiffness /
_cNor Asmaq Baharom
260 _aKuantan, Pahang :
_bUMP,
_c2015
300 _axii, 41 p. :
_bill. (some col.) ;
_c30 cm. +
_e1 CD ROM
500 _aFaculty of Civil Engineering and Earth Resources
502 _aProject Paper (Bachelors of Civil Engineering) -- Universiti Malaysia Pahang – 2015
504 _aBibliography : p. 39-41
520 3 _aProfiled steel sheeting dry board is the new technology that had been used in civil engineering field as slab, roof and wall structure. Profiled steel sheeting dry board panel is a composite structural system consisting of profiled steel sheet (PSS) connected to dry board by simply mechanical connector. It had been used in United Kingdom to substitute the usage of timber formwork on the construction site. Previous researchers were done to determine fire resistance performance and strength of the panel by using different type of methods and material such as dryboard, profiled steel sheeting (PSS), concrete as infill and screw size. This experiment was conducted to determine the stiffness performance on the PSSDB panel when foamed concrete is used as an infill and the result was compared with the PSSDB floor panel without infill. It was also conducted to determine the effect of the screw spacing toward stiffness performance of the floor panel system. This experiment used three (3) samples with differences screw spacing that are Sample 1(100mm), Sample 2 (150mm) and Sample 3(200mm). Compressive strength cube test was done to obtain the strength of the foamed concrete used. Another experiment is bending test, conducted by using Magnus Frame and Apparatus 30 tonnes and attached with transducer to get the data of deflection. The Whiffle-Tree method was use simulate uniformly distribution load to the whole panel system. All the data collected and analyzed to show the performance of the panels system in stiffness. The result shows that the stiffness for Sample 1 is 192 kNm2/m, Sample 2 is 168 kNm2/m and Sample 3 is 162 kNm2/m. It shows that when the screw spacing used increase, the stiffness of the PSSDB floor panel system increased. This is because of the profiled steel sheeting and dry board was stick together firmly by the screw
610 2 0 _aFaculty of Civil Engineering and Earth Resources
_xDissertations
650 0 _aUniversities and Colleges
_xDissertations
650 0 _aTheses
856 4 0 _uhttp://ecollib.ump.edu.my/id/eprint/25586
_zAccess in library only
999 _aVIRTUA40
_c2513
_d2519
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5000*5020*5040*5200*6100*6500*6501*8560*9992