| 000 | 02602nam a2200241 a 4500 | ||
|---|---|---|---|
| 001 | vtls000040407 | ||
| 003 | KUKTEM | ||
| 005 | 20251114204456.0 | ||
| 008 | 090715t2009 my ao f m 000 0 eng d | ||
| 020 | _aTHE0006802(Local) | ||
| 039 | 9 |
_a201905291142 _bamirul _c201107132243 _dVLOAD _c200908141648 _dVLOAD _c200908141628 _dVLOAD _y200907151731 _zkam |
|
| 040 | _aUMP | ||
| 090 | _aTK3091 .I89 2009 rs Bc. | ||
| 100 | 0 | _aMuhamad Iszuan Hamdan | |
| 245 | 1 | 0 |
_aImpact of rotating machines on harmonic distortion in power distribution systems / _cMuhamad Iszuan Bin Hamdan |
| 246 | 3 |
_aImpact of rotating machines on harmonic distortion in power distribution systems _h[electronic resource] |
|
| 260 |
_aKuantan, Pahang : _bUMP, _c2009 |
||
| 300 |
_a65 p. : _bill. (some col.) ; _c30 cm. + _e1 computer disc |
||
| 502 | _aProject paper (Bachelor of Electrical Engineering (Power Systems)) -- Universiti Malaysia Pahang - 2009 | ||
| 520 | 3 | _aHarmonic cause of distortion of the voltages and current waveforms, which have adverse effects on electrical equipment. Harmonics are one of the major power quality concerns. The estimation of harmonics from nonlinear loads is the first step in a harmonic analysis and this may not be straight forward. Rotating machines are considered sources of harmonics because the windings are embedded in slots which are not perfectly sinusoidally distributed resulting in a distorted mmf. Nonsinusoidal voltage applied to electric machines may cause overheating, pulsating torques or noise. In additional to cross the line applications, adjustable speed drive motors are fed from inverter that can produce significant voltage distortion. In induction motor, they can overheat due to the effects of harmonic currents, depending on their frequency, because of additional rotating magnetic fields in the motor. Harmonic produce harmonic fluxes in motors. The harmonic torques tends to rotate motor at different harmonic synchronous speeds. It can produce high frequency currents in rotor circuits. The data which collect from the site project will be inserting into Visualation Basic, VB. The parameters that will be state are voltage, current, frequency, time and total harmonic distortion. The reading will be collect with the different speed of motor. It causes to show how the speeds of motor produce harmonic distortion. Then it wills using the different type of starter motor there are Direct-On-Line, Auto-Transformer and Star-Delta. | |
| 650 | 0 | _aElectric power distribution | |
| 999 |
_aVIRTUA40 _c2677 _d2683 |
||
| 999 | _aVTLSSORT0080*0200*0400*0900*1000*2450*2460*2600*3000*5020*5200*6500*9992 | ||