000 02768nam a2200253 a 4500
001 vtls000058160
003 KUKTEM
005 20251114204508.0
008 120106t2010 my a f m 000 0 eng d
020 _aTHE0004851(Local)
039 9 _a201905161133
_bsmfh
_y201201061835
_zida
040 _aUMP
090 _aTP757 .A75 2010 rs Bc.
100 0 _aMuhammad Arif Ismail
245 1 0 _aPotential natural gas pipe line at Universiti Malaysia Pahang laboratory and residential college unit for future development /
_cMuhammad Arif Ismail
260 _aKuantan, Pahang :
_bUMP,
_c2010
300 _axv, 63 p. :
_bill. ;
_c30 cm. +
_e1 CD-ROM
502 _aProject paper (Bachelor of Chemical Engineering (Gas Technology)) -- Universiti Malaysia Pahang - 2010
504 _aBibliography : p. 45-46
520 3 _aThe consumption of energy has increased as result of rapid economic growth in Malaysia. Realizing the importance of energy, natural gas can be alternative energy source which is more effective and cheap compared to electricity. The main objective of this project is to design the distribution line of natural gas to all residential college units (UKK) at Universiti Malaysia Pahang (UMP) located at Gambang, Kuantan. UMP is located near to gas service station, approximately 500 m with the existing gas service station in Gambang, it is convenient way to tap the natural gas at future point to UMP. Currently, student’s cafeteria using LPG bulk storage for cooking and it is not continuously supply and can disturb their production. Besides that, student also have water heater in their hostel, thus it will affect the electricity bill for every month. The scope of this project are the consumption of load demand that can accommodate for all residential college unit and student’s cafeteria, network piping calculation using Cox’s equation by calculation of load and determine the classification of polyethylene pipe construction, and lastly using PDMS software to draw the pipeline. The method that been used are to calculate all piping size and gas load demand by using Cox’s equation according to standard such as MS930 and ASME B31.8 to make sure that the piping design is safe for the construction. As the result, the total pressure drop from the source to load consumer is below 15% which is acceptable for designing pipeline. The Medium Density polyethylene (MDPE) pipe is use for distribution line construction. Lastly, the piping sizes for MDPE pipe are 2 inches and 3 inches. As the conclusion, natural gas can reduce about 50% the utilities cost compare to electricity.
650 0 _aGas pipelines
650 0 _aNatural gas pipelines
999 _aVIRTUA40
_c3015
_d3021
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5020*5040*5200*6500*6501*9992