000 02940ntm a2200253 a 4500
001 vtls000083928
003 KUKTEM
005 20251117113243.0
008 141121t2013 my a f m 000 0 eng d
020 _aTHE0006394(Local)
039 9 _a201905131441
_bamirul
_c201411211010
_dariffin
_y201411210906
_zariffin
040 _aUMP
090 _aTJ808.6 .H36 2013 r Bc.
100 0 _aHamdi Abdullah Mohammed Mudhsh
245 1 0 _aDesign and analysis of piping system for an open channel flume’s flow /
_cHamdi Abdullah Mohammed Mudhsh
260 _aKuantan, Pahang :
_bUMP ,
_c2013
300 _axiv, 60 p. :
_bill. (some col.) ;
_c30 cm. +
_e1 CD-ROM
502 _aProject paper (Bachelor of Mechanical Engineering)-- Universiti Malaysia Pahang - 2013
504 _aBibliography : p. 46-47
520 3 _aThe increase on the usage of non-renewable energy has caused high demanding on energy supplies. This demand is highly needed for the industrial, transportation, domestic usage and etc. Shortage in the non-renewable energy had caused human to find other alternatives to generate energy. Hence, this research is aim to develop a flume, that later use to generate electricity. However, researcher only focuses on the design and analysis of the piping system of the flume. The objectives of this research is to design piping system of an open channel with less head losses and simulate it using CFD for only single phase perform (not free service), to evaluate the pressure drop in the pipes and to analyses and determine the head losses in the pipe. The instrument used is Solid Work 2012 for technical drawing of the piping system and Computational Fluid Dynamics (CFD) for simulation of the design and analysis. There are four designs of piping system that had been produce which is Design A, Design B, Design C and Design D, the properties measured for all four designs are pressure drop, percentage pressure drop, head loss and velocity. Design A; average percentage of pressure drop is 40.2%, average head loss which is 2.7 m, velocity; inlet velocity is 8.84 m/s and average outlet velocity is 8.75 m/s. Design B; average percentage of pressure drop is 53.6 %, average head loss which is 5.8 m, velocity; inlet velocity is 8.84 m/s and average outlet velocity is 14.31 m/s. Design C; percentage of pressure drop is 38.4 % ,head loss which is 4.4 m, velocity; inlet velocity is 8.84 m/s and outlet velocity is 11.76 m/s. Designs D; percentage of pressure drop is 30.7%, head loss which is 3.1 m, velocity; inlet velocity is 8.84 m/s and outlet velocity is 12.03 m/s. The best design is determined by less percentage of pressure drops, hence from the research findings Design D is the best design since it has the less percentage of pressure drop.
650 0 _aFlumes
650 0 _aRenewable energy sources
999 _aVIRTUA40
_c5541
_d5547
999 _aVTLSSORT0080*0200*0400*0900*1000*2450*2600*3000*5020*5040*5200*6500*6501*9992